To use the Cable Adapter to connect with an IDE 40-pin connector:

Step 1 Turn of the power on the analyzer and the device-under-test

Step 2 Connect the middle connector on the IDE 40-pin Probe Adapter to the 40-pin

connector on the Cable Adapter.

Step 3 Connect one of the end connectors on the IDE 40-pin Probe Adapter to the PHY

subsystem.

Step 4 Connect the other end connector on the IDE 40-pin Probe Adapter to the MAC

subsystem.

Step 5 Connect the Adapter Cable (SCSI) to the MPI ADAPTER connector on the

UWBTracer plug-in.

Step 6 Connect the Adapter Cable (SCSI) to the TO ANALYZER connector on the

Cable Adapter unit.

Step 7 Turn on the power, then start capturing data.

To use the Cable Adapter to connect with a Hirose 68-pin connector:

Follow the same steps as for the IDE 40-pin connector, but use the Hirose 68-pin Probe
Cable and the 68-pin connector on the Cable Adapter.

To use the Board Adapter to connect with a IDE 40-pin connector:

Step 1 Turn off the power on the analyzer and the device under test.

Step 2 Connect one side of the IDE 40-pin Board Adapter to the connector on the MAC

subsystem.

Step 3 Connect the PHY subsystem to the other IDE 40-pin connector on the Board

Adapter.

Step 4 Connect the Adapter Cable (SCSI) to the MPI ADAPTER connector on the

UWBTracer plug-in.

Step 5 Connect the other side of the Adapter Cable (SCSI) to the connector on the

Board Adapter.

Step 6 Turn on the power, then start capturing data.

To use the Board Adapter to connect with a Hirose 68-pin
connector:

Follow the same steps as for the IDE 40-pin connector, but use the Hirose 68-pin Board
Adapter.

To use the Board Adapter to connect with a Hirose 60-pin
connector:

Follow the same steps as for the IDE 40-pin connector, but use the Hirose 60-pin Board
Adapter.