beautypg.com

Properties window – Teledyne LeCroy UWBTracer User Manual User Manual

Page 283

background image

UWBTracer/Trainer User Manual

Chapter 15: Creating and Editing Generation Files

LeCroy Corporation

265

Properties Window

The Properties window lists all properties and their values for the selected module.
Parameters/values can be changed by entering text into the text boxes or by selecting
items from pull-down menus.

For example, the Declarations Default has the properties:

Type: Click Enter to store string entry.

Element Type: Declarations.You cannot modify the number.

include file name list: Default is Uwbgeneration.Ginc and
other_frame_templates.ginc. You can add more .ginc files.

Description: Enter a description.

Element Comment: Default is “Default”. Enter further comments.

Element Unique ID: Default is 16. You cannot modify the number.

Begin has the properties:

Type: Click Enter to store string entry.

Element Type: Begin.You cannot modify this.

Description: Enter a description.

Element Comment: Enter comments.

Element Unique ID: Default is 3. You cannot modify the number.

End has the properties:

Type: Click Enter to store string entry.

Element Type: End.You cannot modify this.

Description: Enter a description.

Element Comment: Enter comments.

Element Unique ID: Default is 6. You cannot modify the number.

The fields which are part of Frame Templates are shown in one of the two following ways

FieldName : n (where n is the number of bits in the fixed-length field. Bit fields
always have a fixed length.)

FieldName : m Bytes (where m is the number of bytes that you specify. Byte fields
may have from 0 to any number of blank separated hex values.)