Chapter 9: Reports
UWBTracer/Trainer User Manual
114
LeCroy Corporation
Setting Traffic Summary Range
You can select a range within the trace file for which items are displayed in the traffic
summary. All occurrences of the item outside of the range are not included in the
summary. You can set the range with respect to particular frame or packet types. Your
choice of these types is context-sensitive and is determined by the current trace decode
level (MPI trace level view, WUSB packet level view, and so on).
In the following example, suppose you have trace decode level set to WUSB packet level
view and suppose the trace contains six MPI frames.
To collect statistics from the third through fifth MPI frames (inclusive):
Step 1 With the trace file open, select Traffic Summary from the Report menu
(or click the Traffic Summary button on the Main tool bar). The Traffic
Summary window appears.
Step 2 Select WiMedia Frames in the left pane of the Traffic Summary window.
The summary for WiMedia Frames appears in the right pane.
Step 3 Click the Select Range button on the Traffic Summary tool bar
Figure 9.11 Selecting Traffic Summary Range
Step 4 The Select Range dialog box appears (Figure 9.12).
Figure 9.12 Select Range Dialog Box