Figure 12.5 select sync channels dialog box – Teledyne LeCroy UWBTracer User Manual User Manual
Page 202

Chapter 12: Recording Options
UWBTracer/Trainer User Manual
184
LeCroy Corporation
Channel Sync Mode
For the analyzer to capture RF traffic, you must synchronize the RF transmission of at
least one device under test (DUT). Use the Channel Sync Mode section to set the
parameters required for synchronizing to a device.
Two modes of operation can be set:
•
Sync to Channel: Directs the analyzer to attempt to synchronize to a specific
channel. In this mode, you can only select a single channel in the Select Sync
Channel window displayed after you click the Set button.
•
Scan Channels: Directs the analyzer to scan the first channel for a specified period
of time, then repeat for the remaining channels. In this mode, you can select
multiple channels in the Select Sync Channel window displayed after you click the
Set button. The system stops recording automatically after all selected channels
have been scanned.
To select the channel or channels, click Set to display the Select Sync Channel(s) dialog
box:
Figure 12.5 Select Sync Channels Dialog Box
The dialog box lists the Channel, Band Group/TF Code, and Band IDs.
Select a checkbox on the left to select a channel. When you are finished selecting
channels, click OK.
Note: Empty packets may be created in either Scan mode.