beautypg.com

Teledyne LeCroy Sierra M6-1 SAS_SATA Protocol Analyzer User Manual User Manual

Page 73

background image

    

Sierra M6‐1 SAS/SATA Protocol Analyzer User Manual

71

Trigger Setup

 Teledyne LeCroy

Figure 2.38: Timeout Dialog

"Start Events" starts the timer in Timeout Trigger and "End Events" triggers the analyzer (if 
first trigger mode is selected) or resets the trigger (if second trigger mode is selected). 
Repetitions of the Start Events are ignored until the End Event is encountered or the timer 
expires.

Select a pattern for Start Events or End Events, enter a Timeout value, then select Trigger 
Mode: 

If End Events occur before timer expires

If timer expires before End Events

Note:

Timeouts can only be configured from the Timeout Pattern dialog. The Timeout Pattern dialog 

allows configuring other patterns as triggers in combination with timeouts. Other pattern dialogs 
do not allow configuration of timeouts.