Advanced Mode (User‐Defined)

102

 

 

Sierra M6‐1 SAS/SATA Protocol Analyzer User Manual

5. If you choose Pattern, you can select patterns for inclusion or exclusion. Clicking the 

Pattern option enables a pattern definition dialog.

Figure 2.74: SAS: Choosing a Pattern

6. Choose pattern(s) and click the +>> button to add them for capture or exclusion. You 

define each pattern the same way as in Easy mode (see 

“Defining Patterns” on 

page 54

).

7. For an output trigger, click the down arrow in the Ext. Out field and choose an 

output trigger level. Note: Do not use the LOW setting in Advanced Mode.

8. To go to another state, click the down arrow in the Go To field and select a state. If 

no other state has been defined, choose New State to add a state.

Set Timers

You can set and use up to three timers for triggering. You can set each timer for each 
state or continue from a timer set in the previous state. The timer defined for a particular 
state starts when entering that state. To set timers, click the ellipses in the Timer field in 
each state and define each of the timers in the Set Timers dialog.

Figure 2.75: Set Timers Dialog

Note:

Three timers are available. You have to set and start each timer in order to continue the next 

timer. For example, you have to start Timer 1, continue it, then set Timer 2 in order to continue 
it. It will not allow you to continue Timer 2 until you first set it.