Sierra M6‐1 SAS/SATA Protocol Analyzer User Manual

189

Port Status

 Teledyne LeCroy

In addition to displaying OOB, Link, Frame, and Error, a display showing the % buffer full 
opens when a trigger occurs.

Figure 3.115: Port Status Window and Capturing Time

1. Pre‐trig capturing (trig is 50%)
2. Trig point (shown by red bar; 36% pre trig was captured)
3. Post‐trig capturing (50% post‐trig was captured and capturing has stopped)

Note:

If sample capture occurs with more than one unit active, additional Port Status windows display.

The OOB, Link, Frame and Error LEDs in the Port Status dialog mimic/follow the LEDs on 
the Front panel of the unit. 

When the LEDs are dim, it indicates they were lit in the past. Pressing the Reset button 
erases this history and the illuminated LEDs are removed from the dialog.

LEDs illuminated

Reset button