Viewer Display

114

 

 

Sierra M6‐1 SAS/SATA Protocol Analyzer User Manual

Figure 3.2: SATA: Packet View of .sts Sample File

3.1.1

Quick View

By default, the Preferences settings enable Quick View. Quick View allows full access to 
the whole trace more quickly, especially when using a Gigabit Ethernet connection. 
However, the trace is NOT written to the host machine’s hard drive. To save the trace, you 
must manually click Save

If you uncheck Quick View in the Preferences to disable Quick View, the trace loads more 
slowly, but is automatically saved to the host machine’s hard drive. When Quick View is 
disabled, the Viewer displays successive parts of trace data as they upload. As soon as a 
trace part uploads, it is available in all trace views. 

If you only need quick successive traces, and do not need to save them, keep the default 
setting to enable Quick View.

If you need to save all captured traces, unchecking the Quick View setting loads traces 
faster, especially for larger traces and slower connections than Gigabit Ethernet.

To refresh the viewer display with more uploaded data, scroll to the end of the trace, 
using scroll bars, page down, arrow down, or CTRL‐End. Newly uploaded data then 
appears there.

Note:

High‐level decoding and statistics are available only after the whole trace has uploaded.

The software automatically switches to full trace view after trace uploading finishes.

Note:

Users must press CTRL Home to go to the beginning of an uploaded trace, and CTRL End to go to 