beautypg.com

Report between cursors – Teledyne LeCroy Sierra M6-1 SAS_SATA Protocol Analyzer User Manual User Manual

Page 128

background image

Teledyne LeCroy

Analysis

126

 

 

Sierra M6‐1 SAS/SATA Protocol Analyzer User Manual

.

Figure 3.23: Enabling Read/Write Statistical Report

Note:

This settings should be enabled before you capture the trace file. 

If you have already captured a trace file and want to create a read/write statistical report 
for the sample, perform the following steps: 

1. Enable the read/write settings as mentioned above.
2. Open the trace file. 
3. Set the X pointer on the first packet in the viewer. 
4. Set the Y pointer on last packet in the viewer. 
5. Save as the trace file using the X to Y option. 

Now the saved trace file will contain the read/write statistical report. 

Report between Cursors

Click the option button next to the From cursor selection drop down list. Then click the 
From down arrow and choose the 1st cursor, click the To down arrow to choose the 2nd 
cursor, and click OK (see 

Figure 3.24 on page 127

). The resulting report has only the 

capture between the cursors.