beautypg.com

1 exporting – Teledyne LeCroy Sierra M6-1 SAS_SATA Protocol Analyzer User Manual User Manual

Page 47

background image

    

Sierra M6‐1 SAS/SATA Protocol Analyzer User Manual

45

Saving a Trace Capture

 Teledyne LeCroy

Figure 2.7: Save As Dialog

You can limit the range of the saved file. You can save:

All Samples

a range between selected cursors

a range between selected Idle, link, commands

range between bookmarks

The Save Filtered Sample checkbox saves a trace file without filtered data. The Apply 
Show/Hide Link Setting 
checkbox filters the saved data further by also applying the 
current status of the port buttons of the toolbar.

2.9.1

Exporting

From the File menu, you can Export to Text/Excel, Export to Trainer, Export Read‐Write 
Command Report, or Export Paired SAS Address Report.