Example 8: Creating a Sequence With Many States #1

270

 

 

Sierra M6‐1 SAS/SATA Protocol Analyzer User Manual

Note:

The states in this sequence have been renamed (do not have their default names). The following 

table summarizes the sequence logic.

TABLE 4.10: Example 8: Logic of Sequence 0

1. Click the New Scenario button in the main library or one of the device libraries. In 

the Scenario Properties dialog, enter the scenario name, description, and direction 
of traffic change.

2. As in previous examples, create the five states for this sequence.
3. In the File menu, select Save Scenario to save the scenario (see 

Figure 4.39 on 

page 271

).

State

Description

Wait for Align (0)

When an Align (0) is received, go to Wait for Align (1).

Wait for Align (1)

If an Align (1) is received next, go to Wait for Align (2);
otherwise, go to Indicate Error.

Wait for Align (2)

If an Align (2) is received next, go to Wait for Align (3);
otherwise, go to Indicate Error.

Wait for Align (3)

If an Align (3) is received next, restart test;
otherwise go to Indicate Error.

Indicate Error

Indicate error and restart test.