Table 11 basic setting > system information – ZyXEL Communications IES-708-22A User Manual
Page 84
Chapter 7 System Information
IES-708-22A User’s Guide
84
The following table describes the labels in this screen.
Table 11 Basic Setting > System Information
LABEL
DESCRIPTION
System Name
This field displays the device's model name, including STU-R/STU-C mode.
ZyNOS F/W Version This field displays the version number of the device’s current firmware including
the date created.
DSL Driver Version
This field displays the Digital Subscriber Line firmware version number.
DSP Code Version
This field displays the Digital Signal Processor firmware version number. This is
the modem code firmware.
Hardware Version
This is the version of the physical device hardware. This field may be blank.
Serial Number
This is the individual identification number assigned to the device at the factory.
This field may be blank.
Ethernet Address
This field refers to the Ethernet MAC (Media Access Control) address of the
device.
Hardware Monitor
Enable
Select this check box to turn the hardware monitor on or clear it to turn the
hardware monitor off.
Temperature Unit
Select C to display all temperature measurements in degrees Celsius. Select F
to display all temperature measurements in degrees Fahrenheit.
Temperature Each
temperature sensor can detect and report the temperature. Temperature
sensor 1 is near the DSL chipset. Temperature sensor 2 is near the central
processing unit. Temperature sensor 3 is at the hardware monitor chip.
Current
This shows the current temperature at this sensor.
MAX
This field displays the maximum temperature measured at this sensor.
MIN
This field displays the minimum temperature measured at this sensor.
Average
This field displays the average temperature measured at this sensor.
Threshold (Low)
This field displays the lowest temperature limit at this sensor.
Threshold (Hi)
This field displays the highest temperature limit at this sensor.
Status
This field displays Normal for temperatures below the threshold and Over for
those above.
Voltage(V)
The power supply for each voltage has a sensor that can detect and report the
voltage.
Current
This is the current voltage reading.
MAX
This field displays the maximum voltage measured at this point.
MIN
This field displays the minimum voltage measured at this point.
Average
This field displays the average voltage measured at this sensor.
Threshold (Low)
This field displays the lowest voltage limit at this sensor.
Threshold (Hi)
This field displays the highest voltage limit at this sensor.
Status
Normal indicates that the voltage is within an acceptable operating range at this
point; otherwise Abnormal is displayed.
Use this section of the screen to configure the hardware monitor threshold
settings.
New threshold
Apply
Configure new threshold settings in the fields below and click Apply to use
them.
Index
This field is a sequential value.