8 alarm history show command, 9 alarm history clear command – ZyXEL Communications IES-708-22A User Manual
Page 273
Chapter 44 Alarm Commands
IES-708-22A User’s Guide
273
44.8 Alarm History Show Command
Syntax:
ras> alarm history show [
[
where
This command displays historic alarms by severity, alarm category, alarm condition and/or
dates.
The following example displays the historic major and critical level alarms.
44.9 Alarm History Clear Command
Syntax:
ras> alarm history clear
ras> alarm history clear
syslog
This displays “V” if the system is to send this alarm to a syslog server. It displays
“-“ if the system does not send this alarm to a syslog server.
severity
This is the alarm severity level (critical, major, minor or info).
clearable
This displays “V” if the alarm clear command removes the alarm from the
system. It displays “-“if the alarm clear command does not remove the alarm
from the system.
Table 91 Log Format (continued)
LABEL
DESCRIPTION
=
Alarm severity. info|minor|major|critical
=
Alarm category. sys|eqpt|enet|dsl|voip
=
Text description for the condition.
=
Start date (yyyy/mm/dd)
=
End date (yyyy/mm/dd)
[for|rev]
=
Display order. for: forward; rev: reverse.
[detail]
=
Display in-depth alarm information.
ras> alarm history show major
no alarm condition severity timestamp source
------ ------ -------------------- -------- -------------- -------
1 enet +down major 01/01 00:00:08 enet 1
2 enet -down major 01/01 00:00:11 enet 1