37
Alarm
This chapter shows you how to display the alarms, sets the severity level of an alarm(s) and
where the system is to send the alarm(s) and set port alarm severity level threshold settings.
37.1 Alarm
The IES-708-22A monitors for equipment, DSL and system alarms and can report them via
SNMP or syslog. You can specify the severity level of an alarm(s) and where the system is to
send the alarm(s). You can also set the alarm severity threshold for recording alarms on an
individual port(s). The system reports an alarm on a port if the alarm has a severity equal to or
higher than the port’s threshold.
37.2 Alarm Status Screen
This screen displays the alarms that are currently in the system.
To open this screen, click Alarm > Alarm Status.
Figure 117 Alarm > Alarm Status
The following table describes the labels in this screen.
Table 81 Alarm > Alarm Status
LABEL
DESCRIPTION
Alarm Event Setup
Click Alarm Event Setup to go to a screen where you can configure the
severity level of an alarm(s) and where the system is to send the alarm(s). See
.
Alarm Port Setup
Click Alarm Port Setup to go to a screen where you can configure the alarm
severity threshold for recording alarms on an individual port(s). See
Alarm Type
Select which type of alarms to display by Severity, or select All to look at all the
alarms.