9 rpvc route show command – ZyXEL Communications IES-708-22A User Manual
Page 359
![background image](/manuals/226434/359/background.png)
Chapter 54 Virtual Channel Management
IES-708-22A User’s Guide
359
This command adds a domain for 2684 routed mode traffic. The domain includes the
subscriber’s LAN IP addresses.
"
You must use the
rpvc gateway set
and the
rpvc set
commands before you
use the
rpvc route set
command.
The following example adds a domain for a CPE device is connected to DSL port 1 on the
IES-708-22A and the 2684 routed mode traffic is to use the PVC identified by VPI 8 and VCI
35. The CPE device’s LAN IP address is 10.10.10.10 and uses a subnet mask of
255.255.255.0. This includes the CPE device’s LAN IP addresses and the IP addresses of the
LAN computers.
54.5.9 RPVC Route Show Command
Syntax:
ras> shdsl rpvc route show
where
This command lists the domains for 2684 routed mode traffic.
=
The subscriber’s CPE LAN IP address in dotted decimal
notation.
/
=
The bit number of the subnet mask of the subscriber’s IP
address. To find the bit number, convert the subnet mask to
binary and add all of the 1’s together. Take “255.255.255.0” for
example. 255 converts to eight 1’s in binary. There are three
255’s, so add three eights together and you get the bit number
(24).
ras> shdsl rpvc route set 1 8 35 10.10.10.1/24
=
The port(s) of the RPVC.
You can specify a single DSL port <1>, all DSL ports <*> or a
list of DSL ports <1,3,5>. You can also include a range of ports
<1,5,6~8>.