ZyXEL Communications IES-708-22A User Manual
Page 134
Chapter 15 xDSL Line Data
IES-708-22A User’s Guide
134
Stuc/Stur SES
The number of Severely Errored Seconds detected by the STU-C and the STU-
R on this DSL port. A Severely Errored Second is defined as a count of 1-
second intervals during which at least 50 CRC anomalies are declared or one or
more LOSW defects are declared. (50 CRC anomalies during a 1-second
interval is equivalent to a 30% errored frame rate for a nominal frame length.)
Stuc/Stur
CRCanomalies
The number of CRC anomalies detected by the STU-C and the STU-R on this
DSL port.
Stuc/Stur
LOSWS
The number of Loss of Sync Word Failure Seconds detected by the STU-C and
the STU-R on this DSL port.
Stuc/Stur UAS
The number of UnAvailable Seconds.detected by the STU-C and the STU-R on
this DSL port. An Unavailable Second is a count of 1-second intervals for which
the SHDSL line is unavailable. The SHDSL line becomes unavailable at the
onset of 10 contiguous SESs. The 10 SESs are included in the unavailable time.
Once unavailable, the SHDSL line becomes available at the onset of 10
contiguous seconds with no SESs. The 10 s with no SESs are excluded from
unavailable time.
Performance (since
last link up)
ES
The number of Errored Seconds that have occurred since the last connection
was established.
SES
The number of Severely Errored Seconds that have occurred since the last
connection was established.
CRCanomalies
The number of CRC anomalies that have occurred since the last connection
was established.
LOSWS
The number of Loss of Sync Word Seconds that have occurred since the last
connection was established.
UAS
The number of UnAvailable Seconds.that have occurred since the last
connection was established.
Segment
Anomaly
The number of Segment Anomalies that have occurred since the last
connection was established. A segment anomaly indicates that a regenerator
operating on a segment has received corrupted data and therefore the
regenerated data is unreliable.
Segment Defect
The number of Segment Defects that have occurred since the last connection
was established. A segment defect indicates that a regenerator has lost SHDSL
synchronization and therefore the regenerated data is unavailable.
15 min, 1day history This section of the screen displays line performance statistics for the current
and previous 15-minute periods, as well as for the current and previous 24
hours.
STUC: This refers to what is detected by the Central Office (CO) end point.
STUR: This refers to what is detected by the Remote (R) end point.
crc
The number of CRC anomalies detected within the period.
es
The number of Errored Seconds detected within the period.
ses
The number of Severely Errored Seconds detected within the period.
losws
The number of Loss of Sync Word Seconds detected within the period.
uas
The number of UnAvailable Seconds detected within the period.
Table 30 Basic Setting > xDSL Line Data > Line Performance (continued)
LABEL
DESCRIPTION