Alarm commands, 1 alarm commands, 2 general alarm command parameters – ZyXEL Communications IES-708-22A User Manual
Page 269: 3 alarm show command, Chapter 44 alarm commands, Table 90 general alarm command parameters, Alarm commands (269)

IES-708-22A User’s Guide
269
C
H A P T E R
44
Alarm Commands
This chapter describes the alarm management commands.
44.1 Alarm Commands
Use these commands to view, customize and clear alarms. You can also set the device to report
alarms to an SNMP or syslog server that you specify.
44.2 General Alarm Command Parameters
The following table describes commonly used alarm command parameter notation.
44.3 Alarm Show Command
Syntax:
ras> alarm show [
[
where
Table 90 General Alarm Command Parameters
NOTATION
DESCRIPTION
Specify a category of alarms.
eqpt represents equipment alarms.
dsl represents Digital Subscriber Line (DSL) alarms.
enet represents Ethernet alarms.
sys represents system alarms.
all specifies every alarm category.
Specify an alarm severity level (critical, major, minor, info or all). Critical alarms
are the most severe, major alarms are the second most severe, minor alarms
are the third most severe and info alarms are the least severe.
This is the text description for the condition under which the alarm applies. Use
the alarm tablelist to find alarm conditions.
=
Alarm severity. info|minor|major|critical
=
Alarm category. sys|eqpt|enet|dsl|voip
=
Text description for the condition.