Verifying parameter changes: verify menu, Refer to verifying parameter, 3 the drive and programming modes – Yaskawa L1000E AC Drive Technical Manual for CIMR-LE Models for Elevator Applications User Manual
Page 98

4.3 The Drive and Programming Modes
98
YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual
◆ Verifying Parameter Changes: Verify Menu
The Verify Menu lists edited parameters from the Programming Mode or as a result of Auto-Tuning. The Verify Menu
helps determine which settings have been changed, and is particularly useful when replacing a drive. If no settings have
been changed, the Verify Menu will read “None”. The Verify Menu also allows users to quickly access and re-edit any
parameter settings that have been changed.
Note: The Verify Menu will not display parameters from the A1 group (except for A1-02, Control Method Selection) even if those
parameters have been changed from their default settings.
The following example is a continuation of the steps above. Here, parameter C1-02 is accessed using the Verify Menu,
and is changed again from 1.50 s to 2.50 s.
The steps below are an example of how to check the list of edited parameters:
12.
Press
as many times as necessary to return to the initial display.
Step
Display/Result
1.
Turn on the power to the drive. The initial display appears.
2.
Press
or
until the display shows the top of the Verify Menu.
3.
Press
to enter the list of parameters that have been edited from their original default settings.
If parameters other than C1-02 have been changed, use
or
to scroll until C1-02 appears.
4.
Press
to access the setting value. Left digit flashes.
Step
Display/Result
- MODE -
U1-01= 0.00%
U1-02= 0.00%
U1-03= 0.00A
DRV
Speed Ref (OPR)
Rdy
RSEQ
LREF
FWD
- MODE -
U1-01= 0.00%
U1-02= 0.00%
U1-03= 0.00A
DRV
Speed Ref (OPR)
Rdy
RSEQ
LREF
FWD
- MODE -
PRG
Modified Consts
HELP
DATA
FWD
Modified
X Parameters
C1-02
= 2.50sec
(0.0~600.00)
“1.50sec”
FWD
- VERIFY -
PRG
Decel Ramp 1
Rdy
Home
DATA
FWD
C1-01=
0
02.50sec
(0.0~600.00)
“1.50sec”
- VERIFY - PRG
Decel Ramp 1
Rdy
Home
DATA