8.4 Option Card Installation
340
YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual
3.
Connect one end of the ground wire (H) to the ground terminal (I) using one of the remaining screws (C). Connect
the other end of the ground wire (H) to the remaining ground terminal and installation hole on the option (B) using
the last remaining provided screw (C).
Figure 8.5
Figure 8.5 Connect the Ground Wire
Note: 1. The option package includes two ground wires. Use the longer wire when plugging the option into connector CN5-C on the drive side.
Use the shorter wire when plugging the option into connector CN5-B. Refer to the option card instruction manual for more
information.
2. There are two screw holes on the drive for use as ground terminals (I). When connecting three options, two ground wires will need to
share the same drive ground terminal.
4.
Prepare and connect the wire ends as shown in
and
Refer to Wire Gauges, Tightening
Torque, and Crimp Terminals on page 345
to confirm that the proper tightening torque is applied to each
terminal. Take particular precaution to ensure that each wire is properly connected and wire insulation is not
accidentally pinched into electrical terminals.
WARNING! Fire Hazard. Tighten all terminal screws according to the specified tightening torque. Loose electrical connections could
result in death or serious injury by fire due to overheating electrical connections. Tightening screws beyond the specified tightening
torque may result in erroneous operation, damage to the terminal block, or cause a fire.
NOTICE: Heat shrink tubing or electrical tape may be required to ensure that cable shielding does not contact other wiring. Insufficient
insulation may cause a short circuit and damage the option or drive.
Figure 8.6
Figure 8.6 Preparing Ends of Shielded Cable
Figure 8.7
Figure 8.7 Preparing and Connecting Cable Wiring
I
B
H
C
YEA_com
Insulation
Shield sheath
Shield
PG option terminal
PG at motor
FE/SD
Ground Terminal
(Insulate with electrical tape
or shrink tubing)
B
3
Option terminal block
Preparing wire ends:
Screwdriver blade size
about 5.5 mm (7/32”)
When not using
crimped insulated
sleeves
Pull back the shielding and lightly
twist the end with fingers, keeping
the ends from fraying.
Shielded cable
(do not solder ends)
Loosen the screws and
insert the wire into the
opening on the terminal block.
Blade depth of
0.4 mm or less
Blade width of
2.5 mm or less