8.4 Option Card Installation

342

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

Connection Diagram of PG-X3

Refer to

Table 8.10

for a detailed description of the option board terminal functions.

Figure 8.9 PG-X3 Option and PG Encoder Connection Diagram

<1> The PG-X3 Option reads a maximum input frequency from the PG of 300 kHz. Be sure to select a PG with a maximum output pulse frequency

of 300 kHz when operating at maximum speed.

U/T1
V/T2

W/T3

R/L1
S/L2
T/L3

A+
A

B

Z

B+

Z+

a+
a

b

z

b+

z+

FE

IP
IG

IP12

IP5

IG

TB1

SG

SD

TB2

PG

NC

CN5-C

A

pulse

monitor signal

Ground wire

B

pulse

monitor signal

Z pulse monitor signal

YASKAWA

Drive

PG

X3

Option

CN3

M

FE

twisted-pair shielded line

main circuit terminal

control circuit terminal

X3