O3: copy function, O3-01 copy function selection, O3-02 copy allowed selection – Yaskawa L1000E AC Drive Technical Manual for CIMR-LE Models for Elevator Applications User Manual
Page 244

5.10 o: Operator Related Settings
244
YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual
■
o2-06: Operation Selection when Digital Operator is Disconnected
Determines whether the drive will stop when the digital operator is removed in LOCAL mode or when b1-02 is set to 0.
When the operator is reconnected, the display will indicate that it was disconnected.
Setting 0: Continue operation
The operation is continued.
Setting 1: Trigger a fault
The operation is stopped and an “oPr” fault is triggered. The motor coasts to stop.
◆ o3: Copy Function
These parameters control the Copy function of the digital operator. The Copy function stores parameter settings into the
memory of the digital operator to facilitate the transfer of those settings to other drives that are the same model, capacity,
and same control mode setting.
Refer to Copy Function Related Displays on page 301
for a description of errors and
displays.
■
o3-01 Copy Function Selection
Instructs the drive to Read, Write, or Verify parameter settings.
Setting 0: Copy Select (no function)
Setting 1: INV
→ OP READ
Copies all parameters from the drive to the digital operator.
Note: The copy protection for the digital operator is enabled by default. Set o3-02 to 1 to unlock copy protection.
Setting 2: OP
→ INV WRITE
Compares the parameters in the drive with the parameter settings saved on the digital operator for matches.
Setting 3: OP
↔ INV VERIFY
Parameters in the drive are compared with the parameter settings saved on the digital operator to see if they match.
■
o3-02 Copy Allowed Selection
Allows and restricts the use of the Copy function.
Setting 0: Disabled
Setting 1: Enabled
No.
Parameter Name
Setting Range
Default
o2-06
Digital Operator Disconnection Operation
0 or 1
0
No.
Parameter Name
Setting Range
Default
o3-01
Copy Function Selection
0 to 3
0
No.
Parameter Name
Setting Range
Default
o3-02
Copy Allowed Selection
0 or 1
0