L8: drive protection, L8-02, Refer to l8-02 – Yaskawa L1000E AC Drive Technical Manual for CIMR-LE Models for Elevator Applications User Manual
Page 225: V/pm control modes, L7-16: torque limit process at start, L8-02: overheat alarm level, L8-03: overheat pre-alarm operation selection, 8 l: protection functions

5.8 L: Protection Functions
YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual
225
P
a
ra
me
te
r De
ta
ils
5
■
L7-01 to L7-04: Torque Limits
These parameters set the torque limits in each operation mode.
A setting of 100% is equal to the motor rated torque.
■
L7-16: Torque Limit Process at Start
Assigns a time filter to allow the torque limit to build at start.
Setting 0: Disabled
Toque limit is created at start without a delay time. Disable L7-16 to maximize response time when the application
requires sudden acceleration or deceleration at start.
Setting 1: Enabled
A time filter is added to allow the torque limit to build at start.
◆ L8: Drive Protection
■
L8-02: Overheat Alarm Level
Sets the overheat alarm (oH) detection level.
The drive will output an alarm when the heatsink temperature exceeds the alarm level set in parameter L8-02.
When an output terminal is set for the oH pre-alarm (H2- = 20), the switch will close when the heatsink temperature
rises above L8-02.
■
L8-03: Overheat Pre-Alarm Operation Selection
Sets the operation when an overheat pre-alarm is detected.
Setting 0: Ramp to stop
If an overheat alarm occurs, the drive decelerates to stop using the deceleration ramp currently selected. If a digital output
is programmed for “fault” (H2- = E), this output will be triggered.
Setting 1: Coast to stop
If heatsink overheat (oH) occurs, the drive switches off the output and the motor coasts to stop. If a digital output is
programmed for “fault” (H2- = E), this output will be triggered.
Setting 2: Fast Stop
If an overheat alarm occurs, the drive decelerates to stop using the Fast Stop ramp (C1-09). If a digital output is
programmed for “fault” (H2- = E), this output will be triggered.
No.
Parameter Name
Setting Range
Default
L7-01
Forward Torque Limit
0 to 300%
200%
L7-02
Reverse Torque Limit
0 to 300%
200%
L7-03
Forward Regenerative Torque Limit
0 to 300%
200%
L7-04
Reverse Regenerative Torque Limit
0 to 300%
200%
No.
Parameter Name
Setting Range
Default
L7-16
Torque Limit Process at Start
0 to 1
1
No.
Parameter Name
Setting Range
Default
L8-02
Overheat Alarm Level
50 to 150°C
Determined by o2-04
No.
Parameter Name
Setting Range
Default
L8-03
Overheat Pre-Alarm Operation Selection
0 to 3
3