4.5 Auto-Tuning
YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual
117
St
ar
t-
U
p
Pr
og
ra
m
m
in
g
&
Op
er
at
io
n
4
■
T1-10: Motor Rated Slip
Sets the rated slip for the motor.
The default setting displayed is the motor rated slip for a Yaskawa motor calculated from the output power set in T1-02.
Enter the data listed on the motor test report.
◆ Parameter Settings during PM Motor Auto-Tuning: T2
The T2- parameters are used to set the Auto-Tuning input data for PM motor tuning.
■
T2-01: PM Auto-Tuning Mode Selection
Selects the type of Auto-Tuning to be performed.
Refer to Auto-Tuning for Permanent Magnet Motors on page 110
for
details on different types of Auto-Tuning.
Setting 0: Motor Data Input
Setting 1: PM Stationary Auto-Tuning
Setting 2: PM Stationary Stator Resistance Auto-Tuning
Setting 3: Initial Magnet Pole Search Parameters Auto-Tuning
Setting 4: Stationary PG Encoder Offset Auto-Tuning
Setting 10: Rotational PG Encoder Offset Auto-Tuning
Setting 11: Rotational Back EMF Constant Auto-Tuning
Setting 12: Auto-Tuning of PG-E3 Encoder Characteristics
■
T2-04: PM Motor Rated Power
Specifies the PM motor rated power in kilowatts.
■
T2-05: PM Motor Rated Voltage
Sets the PM motor rated voltage.
■
T2-06: PM Motor Rated Current
Enter the PM motor rated current in amps.
No.
Parameter Name
Setting Range
Default
T1-10
Motor Rated Slip
0.00 to 20.00 Hz
–
No.
<1> Auto-Tuning of PG-E3 encoder characteristics requires a PG-E3 option with software version 1102 or later. To identify the PG-E3 software
version, refer to the PG-E3 labeling on the option in the field designated “C/N” (S + four-digit number).
Parameter Name
Setting Range
Default
T2-01
PM Auto-Tuning Mode Selection
0 to 4, 10 to 12
0
No.
Parameter Name
Setting Range
Default
T2-04
PM Motor Rated Power
0.00 to 650.00 kW
Depending on o2-04
No.
Parameter Name
Setting Range
Default
<1> Values shown are specific to 200 V class drives. Double value for 400 V class drives.
T2-05
PM Motor Rated Voltage
0.0 to 255.0 V
200.0 V
No.
Parameter Name
Setting Range
Default
T2-06
PM Motor Rated Current
10% to 200% of the drive rated
current.
Depending on o2-04