4.3 The Drive and Programming Modes

The drive has a Drive Mode to operate the motor and a Programming Mode to edit parameter settings.

Drive Mode: In Drive Mode the user can operate the motor and observe U Monitor parameters. Parameter settings cannot
be edited or changed when in Drive Mode.

Programming Mode: In Programming Mode the user can edit and verify parameter settings and perform Auto-Tuning.
The drive will not accept an Up/down command when the digital operator is in the Programming Mode unless parameter
b1-08 is set to 1 to allow an Up/down command.

Note: 1. If b1-08 is set to 0, the drive will only accept an Up/Down command in Drive Mode. After editing parameters, the user must exit the

Programming Mode and enter Drive Mode before operating the motor.

2. Set b1-08 to 1 to allow the drive to run the motor while in Programming Mode.

Navigating the Drive and Programming Modes

The drive is set to operate in Drive Mode when it is first powered up. Switch between display screens by using the

and

keys.

Mode

Contents

Operator Display

Description

Power Up

Speed Reference

(default)

This display screen allows the user to monitor and change the speed reference while the drive is running.

Refer to

The Drive and Programming Modes on page 95

.

Note: The user can select the data displayed when the drive is first powered up with parameter o1-02.

Drive Mode

Monitor Display

Lists the monitor parameters (U†-†† parameters) available in the drive.
Press the Enter Key and then use the Up, Down, ESC, and Reset keys to navigate through the drive monitors.

Programming

Mode

Verify Menu

Lists all parameters that have been edited or changed from default settings.

Refer to Verifying Parameter

Changes: Verify Menu on page 98

.

Setup Group

A select list of parameters necessary to get the drive operating quickly.

Refer to Using the Setup Group on

page 99

.

Parameter Setting

Mode

Allows the user to access and edit all parameter settings.

Refer to Parameter List on page 365

.

FWD

- MODE -

U1-01= 0.00%

U1-02= 0.00%
U1-03= 0.00A

DRV

Speed Ref (OPR)

Rdy

RSEQ
LREF

YEA_com

- MODE -

U1-01= 0.00%

U1-02= 0.00%
U1-03= 0.00A

DRV

Monitor Menu

Rdy

RSEQ
LREF

FWD

YEA_com

- MODE -

PRG

Modified Consts

HELP

DATA

FWD

Modified

X Parameters

YEA_com

HELP

- MODE -

PRG

Quick Setting

DATA

FWD

YEA_com

HELP

- MODE -

PRG

DATA

Programming

FWD

YEA_com