4.3 The Drive and Programming Modes
YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual
95
St
ar
t-
U
p
Pr
og
ra
m
m
in
g
&
Op
er
at
io
n
4
4.3 The Drive and Programming Modes
The drive has a Drive Mode to operate the motor and a Programming Mode to edit parameter settings.
Drive Mode: In Drive Mode the user can operate the motor and observe U Monitor parameters. Parameter settings cannot
be edited or changed when in Drive Mode.
Programming Mode: In Programming Mode the user can edit and verify parameter settings and perform Auto-Tuning.
The drive will not accept an Up/down command when the digital operator is in the Programming Mode unless parameter
b1-08 is set to 1 to allow an Up/down command.
Note: 1. If b1-08 is set to 0, the drive will only accept an Up/Down command in Drive Mode. After editing parameters, the user must exit the
Programming Mode and enter Drive Mode before operating the motor.
2. Set b1-08 to 1 to allow the drive to run the motor while in Programming Mode.
◆ Navigating the Drive and Programming Modes
The drive is set to operate in Drive Mode when it is first powered up. Switch between display screens by using the
and
keys.
Mode
Contents
Operator Display
Description
Power Up
Speed Reference
(default)
This display screen allows the user to monitor and change the speed reference while the drive is running.
The Drive and Programming Modes on page 95
.
Note: The user can select the data displayed when the drive is first powered up with parameter o1-02.
Drive Mode
Monitor Display
Lists the monitor parameters (U- parameters) available in the drive.
Press the Enter Key and then use the Up, Down, ESC, and Reset keys to navigate through the drive monitors.
Programming
Mode
Verify Menu
Lists all parameters that have been edited or changed from default settings.
Changes: Verify Menu on page 98
.
Setup Group
A select list of parameters necessary to get the drive operating quickly.
Refer to Using the Setup Group on
Parameter Setting
Mode
Allows the user to access and edit all parameter settings.
Refer to Parameter List on page 365
.
FWD
- MODE -
U1-01= 0.00%
U1-02= 0.00%
U1-03= 0.00A
DRV
Speed Ref (OPR)
Rdy
RSEQ
LREF
YEA_com
- MODE -
U1-01= 0.00%
U1-02= 0.00%
U1-03= 0.00A
DRV
Monitor Menu
Rdy
RSEQ
LREF
FWD
YEA_com
- MODE -
PRG
Modified Consts
HELP
DATA
FWD
Modified
X Parameters
YEA_com
HELP
- MODE -
PRG
Quick Setting
DATA
FWD
YEA_com
HELP
- MODE -
PRG
DATA
Programming
FWD
YEA_com