8.2 Drive Options and Peripheral Devices
336
YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual
Interface Options
Remote Operator Cable
WV001/WV003
Extension cable (1 m or 3 m) to connect the digital operator for
remote operation
RJ-45, 8 pin straight through, UTP CAT5e cable
USB Copy Unit
JVOP-181
Allows the user to copy and verify parameter settings between
drives. Can also be used as an adapter to connect the drive to
the USB port on a PC.
Attachment
Installation Support Set A
EZZ020642A
For installing the digital operator keypad on the outside of an
enclosure panel that houses the drive. Uses screws to secure the
operator.
Installation Support Set B
EZZ020642B
For installing the digital operator keypad on the outside of an
enclosure panel that houses the drive.
Uses nuts to secure the operator for installations where screws
are not practical.
Others
24 V Power Supply
200 V class: PS-A10LB
400 V class: PS-A10HB
Provides power to the control circuit and option boards in the
event of power loss. Allows the user to monitor drive settings
and fault information when the main circuit has no power.
—
DriveWizard Plus
—
PC tool for drive setup and parameter management
Communication Options
Complementary Signal Encoder
PG-B3
For speed feedback input by connecting a motor encoder
Input: 3 track (can be used with one or two tracks), for HTL
encoder connection, 50 kHz max
Output: 3 track, open collector
Encoder power supply: 12 V, max current 200 mA
Line Driver Encoder
PG-X3
For speed feedback input by connecting a motor encoder
Input: 3 track (can be used with one or two tracks), line driver,
300 kHz max
Output: 3 track, line driver
Encoder power supply: 5 V or 12 V, max current 200 mA
EnDat Encoder
PG-F3
Encoder type: EnDat 2.1/01, EnDat 2.2/01, EnDat 2.2/22
(HEIDENHAIN)
Maximum input frequency: 20 kHz
Pulse monitor: Matches RS-422 level
Output voltage: 5 V
±5%, 8 V±10%
Maximum output current: 200 mA
Wiring length: 20 m max. for the encoder, 30 m max. for the
pulse monitor
ERN1387 Encoder
PG-E3
Encoder type: ERN1387 (HEIDENHAIN)
Maximum input frequency: 20 kHz
Pulse monitor: Matches RS-422 level
Output voltage: 5 V
±5%
Maximum output current: 200 mA
Wiring length: 20 m max. for the encoder, 10 m max. for the
pulse monitor
Analog Monitor
AO-A3
Provides extra analog output terminals for monitoring drive
status.
Output channels: 2
Output voltage: -10 to 10 V, 11 bit (signed)
Digital Input
DI-A3
Used to set the speed reference by digital inputs
Input channels: 18 (including SET signal and SIGN signal)
Input signal type: BCD 16 bit (4 digit), 12 bit (3 digit), 8 bit (2
digit)
Input signal: 24 Vdc, 8 mA
Digital Output
DO-A3
Provides extra insulated digital outputs for monitoring drive
status.
Photocoupler relays: 6 (48 V, up to 50 mA)
Contact relays: 2 (250 Vac/up to 1 A, 30 Vdc/up to 1 A)
CANopen
SI-S3
Connects to a CANopen network
Option
Model Number
Description
Co
py
Ve
rify
Re
ad
LOCK
YA
S
K
A
W
A
JVOP-181
USB Copy Unit
COM
E
RR