Rescue operation torque limit, 6 setup procedure for elevator applications – Yaskawa L1000E AC Drive Technical Manual for CIMR-LE Models for Elevator Applications User Manual
Page 141

4.6 Setup Procedure for Elevator Applications
YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual
141
St
ar
t-
U
p
Pr
og
ra
m
m
in
g
&
Op
er
at
io
n
4
7.
Use a Phillips screwdriver (M4) to fasten the screw that holds the CN19 connector cover in place.
NOTICE: Use the screw provided to fasten the connector cover into place. Using a different screw may damage the internal drive
components.
Figure 4.35
Figure 4.40 Reattaching the CN19 Connector Cover
Figure 4.36
Figure 4.41 Drive and Battery CN19 Connection Complete
■
Rescue Operation Torque Limit
The Torque Limit During Rescue Operation is set in parameter S4-05. After Rescue Operation is complete, the drive
utilizes to the torque limits set in the L7 parameters.
PWR
LED MONITOR JVOP-184
RUN DS1 DS2
RUN DS1 DS2
STATUS
READY
RUN
ALARM(RUN)
PGOH,LT
BB,HBB
EF,SE
Other Fault
OV,UV
OH,OL
OC,GF,SC,PGO
CPF,OFA,OFB,OFC
:LIGHT :BLINK :LIGHT OFF
Connect
to battery
バッテリに接続
PWR
LED MONITOR JVOP-184
RUN DS1 DS2
RUN DS1 DS2
STATUS
READY
RUN
ALARM(RUN)
PGOH,LT
BB,HBB
EF,SE
Other Fault
OV,UV
OH,OL
OC,GF,SC,PGO
CPF,OFA,OFB,OFC
:LIGHT :BLINK :LIGHT OFF