5.1 A: Initialization
152
YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual
Notes on Parameter Initialization
will not be reset when the drive is initialized by setting A1-03 = 2220 or 3330.
Although the control mode in A1-02 is not reset when A1-03 is set to 2220 or 3330, it may change when an application
preset is selected.
Table 5.1 Parameters not Changed by Drive Initialization
■
A1-04, A1-05: Password and Password Setting
Parameter A1-04 enters the password when the drive is locked; parameter A1-05 is a hidden parameter that sets the
password.
How to use the Password
The user can set a password in parameter A1-05 to restrict access to the drive. The password must be entered to A1-04 to
unlock parameter access (i.e., parameter setting A1-04 must match the value programmed into A1-05). The following
parameters cannot be viewed or edited until the value entered to A1-04 correctly matches the value set to A1-05: A1-01,
A1-02, A1-03, A1-06, and A2-01 through A2-33.
The instructions below demonstrate how to set password “1234”. An explanation follows on how to enter that password
to unlock the parameters.
Table 5.2 Setting the Password for Parameter Lock
No.
Parameter Name
A1-00
Language Selection
A1-02
Control Method Selection
E1-03
V/f Pattern Selection
E5-02
Motor Rated Capacity (for PM)
E5-03
Motor Rated Current (for PM)
E5-04
Motor Poles (for PM)
E5-05
Motor Stator Resistance (for PM)
E5-06
Motor d-Axis Inductance (for PM)
E5-07
Motor q-Axis Inductance (for PM)
E5-09
Motor Induction Voltage Constant 1 (for PM)
E5-24
Motor lnduction Voltage Constant 2
F6-
Communications Parameter (initialized when F6-08 = 1)
L8-35
Installation Selection
o2-04
Drive Model Selection
No.
Parameter Name
Setting Range
Default
A1-04
Password
0000 to 9999
0000
A1-05
Password Setting
Step
Display/Result
1.
Turn on the power to the drive. The initial display appears.
2.
Press
or
until the Parameter Setting Mode screen appears.
3.
Press
to enter the parameter menu tree.
- MODE -
U1-01= 0.00%
U1-02= 0.00%
U1-03= 0.00A
DRV
Speed Ref (OPR)
Rdy
RSEQ
LREF
FWD
HELP
- MODE -
PRG
DATA
Programming
FWD
←
→
-PRMSET-
Initialization
Select Language
PRG
FWD
A
1-00=
0