Removing the cooling fan, Yea _tm only yea _tm only – Yaskawa L1000E AC Drive Technical Manual for CIMR-LE Models for Elevator Applications User Manual
Page 317

7.4 Drive Cooling Fans and Circulation Fans
YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual
317
Pe
ri
od
ic
In
spe
ct
io
n
&
Main
tenan
ce
7
◆ Cooling Fan Replacement: 2A0018 to 2A0094 and 4A0009 to 4A0049
WARNING! Electrical Shock Hazard. Do not connect or disconnect wiring while the power is on. Failure to comply can result in serious
personal injury. Before servicing the drive, disconnect all power to the equipment. The internal capacitor remains charged even after
the power supply is turned off. After shutting off the power, wait for at least the amount of time specified on the drive before touching
any components.
CAUTION! Burn Hazard. Do not touch a hot drive heatsink. Failure to comply could result in minor or moderate injury. Shut off the
power to the drive when replacing the cooling fan. To prevent burns, wait at least 15 minutes and ensure the heatsink has cooled down.
NOTICE: Equipment Hazard. Follow cooling fan replacement instructions. The cooling fan cannot operate properly when it is installed
incorrectly and could seriously damage the drive. Follow the instructions in this manual to replace the cooling fan, making sure that the
label is on top before inserting the cooling fan into the drive. To ensure maximum useful product life, replace both cooling fans when
performing maintenance.
■
Removing the Cooling Fan
1.
Depress the right and left sides of the fan cover hooks and pull upward. Remove the fan cover from the top of the
drive. The following figure illustrates a drive with a single cooling fan.
Figure 7.2
Figure 7.2 Removing the Fan Cover: 2A0018 to 2A0094, 4A0009 to 4A0049
2.
Remove the cooling fan cartridge. Disconnect the pluggable connector and remove the fan.
Figure 7.3
Figure 7.3 Removing the Cooling Fan: 2A0018 to 2A0094, 4A0009 to 4A0049
YEA
_TM
only
YEA
_TM
only