Table 6.4 Minor Fault and Alarm Displays
Digital Operator Display
Name
Minor Fault Output
(H2- = 10)
Page
LED Operator
LCD Operator
<1> Output when H2- = 2F.
AEr
Node ID Setting Error (CANopen)
YES
bb
Drive Baseblock
No output
boL
Braking Transistor Overload
YES
bUS
Option Communication Error
YES
CALL
Serial Communication Stand By
YES
CE
MEMOBUS/Modbus Communication Error
YES
CrST
Cannot Reset
YES
dEv
Speed Deviation (for Control Mode with Encoder)
YES
EF
Up/Down Command Error
YES
EF0
Option Card External Fault
YES
to
EF3 to EF8
External Fault (input terminal S3 to S8)
YES
Hbb
Safe Disable Circuit Fault Signal (H1-HC, H2-HC) Release
L8-88 = 0: YES
L8-88 = 1: No (default)
HbbF
Safe Disable Circuit Fault Signal (H1-HC, H2-HC) Release
L8-88 = 0: YES
L8-88 = 1: No (default)
HCA
High Current Alarm
YES
LT-1
Cooling Fan Maintenance Time
No output
LT-2
Capacitor Maintenance Time
No output
LT-3
Soft Charge Bypass Relay Maintenance Time
No output
LT-4
IGBT Maintenance Time (90%)
No output
oH
Heatsink Overheat
YES
oL3
Overtorque Detection 1
YES
oL4
Overtorque Detection 2
YES
oS
Overspeed (for Control Mode with Encoder)
YES
ov
DC Bus Overvoltage
YES
PASS
MEMOBUS/Modbus Comm. Test Mode Complete
No output
PGo
Encoder Disconnected (for Control Mode with Encoder)
YES
PGoH
Encoder Disconnected (when using an encoder)
YES
SE
MEMOBUS/Modbus Self Test Failed
YES
TrPC
IGBT Maintenance Time (90%)
YES
UL3
Undertorque Detection 1
YES
UL4
Undertorque Detection 2
YES
Uv
Undervoltage
YES
voF
Output Voltage Detection Error
YES