Auto-tuning for permanent magnet motors, 5 auto-tuning, Table 4.8 auto-tuning input data – Yaskawa L1000E AC Drive Technical Manual for CIMR-LE Models for Elevator Applications User Manual
Page 110: 1> input data is needed for clv/pm only, 1> depends on t2-13 setting

4.5 Auto-Tuning
110
YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual
■
Auto-Tuning for Permanent Magnet Motors
Automatically sets the V/f pattern and motor parameters E1-, E5-, and some F1- parameters for speed
feedback detection.
Table 4.7 Types of Auto-Tuning for Permanent Magnet Motors
lists the data that must be entered for Auto-Tuning. Make sure the data is available before starting Auto-Tuning.
The information needed is usually listed on the motor nameplate or in the motor test report provided by the motor
manufacturer. Also refer to
Flowchart C: Auto-Tuning for PM Motors on page 107
for details on the tuning mode
selection and the tuning process.
Table 4.8 Auto-Tuning Input Data
Number of Motor Poles
T1-06
–
YES
YES
N/A
YES
Motor Rated Speed
T1-07
r/min
YES
YES
N/A
YES
PG Number of Pulses per Revolution
T1-08
–
YES
YES
N/A
Motor No-load Current
T1-09
A
N/A
YES
N/A
YES
Motor Rated Slip
T1-10
Hz
N/A
N/A
N/A
YES
<1> Input data is needed for CLV/PM only.
Type
Setting
Requirements and Benefits
Motor Data Input
<1> Auto-Tuning of PG-E3 encoder characteristics requires a PG-E3 option with software version 1102 or later. To identify the PG-E3 software
version, refer to the PG-E3 labeling on the option in the field designated “C/N” (S + four-digit number).
T2-01 = 0
• Use if a motor test report is available
• Input motor data from the motor test report. Convert data into the correct unit before inputting data if necessary.
• Motor does not rotate during Auto-Tuning
Stationary Auto-Tuning
T2-01 = 1
• Use if a motor test report is not available
• Input motor data from the motor name plate. Make sure to convert data into the correct units. The drive automatically calculates the
motor data.
Stationary Stator Resistance Auto-
Tuning
T2-01 = 2
• Tunes stator resistance only.
• Should be performed if the motor cabling has changed.
Rotational Back EMF Constant
Auto-Tuning
T2-01 = 11
• Use if a motor test is not available
• Tunes the Motor Induction Voltage only
• Should be performed after Motor data are set and the encoder offset is adjusted.
• The motor must be uncoupled from the mechanical system (remove ropes).
Auto-Tuning of PG-E3 Encoder
Characteristics
T2-01 = 12
Use in CLV/PM control mode to obtain accurate position data from the motor rotor for driving a PM motor.
Input Value
<1> Depends on T2-13 setting.
Input
Parameter
Unit
Tuning Type (T2-01)
0
Motor
Parameter
Settings
1
Stationary
2
Stationary
Stator
Resistance
3
Initial Magnet
Pole Search
Parameters
Auto-Tuning
4
Encoder
Offset
Stationary
Auto-Tuning
10
Encoder
Offset
Rotational
Auto-Tuning
11
Back EMF
Constant
Control Mode
A1-02
–
7
7
7
7
7
7
7
Motor Rated Power
T2-04
kW
Yes
Yes
N/A
N/A
N/A
N/A
N/A
Motor Rated Voltage
T2-05
V
Yes
Yes
N/A
N/A
N/A
N/A
N/A
Motor Rated Current
T2-06
A
Yes
Yes
Yes
N/A
N/A
N/A
N/A
Number of Motor Poles
T2-08
N/A
Yes
Yes
N/A
N/A
N/A
N/A
N/A
Motor Rated Speed
T2-09
r/min
Yes
Yes
N/A
N/A
N/A
N/A
N/A
Stator 1 Phase Resistance
T2-10
Ω
Yes
N/A
N/A
N/A
N/A
N/A
N/A
d-Axis Inductance
T2-11
mH
Yes
N/A
N/A
N/A
N/A
N/A
N/A
q-Axis Inductance
T2-12
mH
Yes
N/A
N/A
N/A
N/A
N/A
N/A
Induced Voltage Constant Unit
Selection
T2-13
N/A
Yes
N/A
N/A
N/A
N/A
N/A
N/A
Voltage Constant
T2-14
Yes
N/A
N/A
N/A
N/A
N/A
N/A
PG Number of Pulses per
Revolution
T2-16
N/A
Yes
Yes
N/A
N/A
N/A
N/A
N/A
Z Pulse Offset
T2-17
deg (mech.)
Yes
N/A
N/A
N/A
N/A
N/A
N/A
Input Value
Input Parameter
Unit
Tuning Type (T1-01)
0
Standard
1
Stationary 1
2
Line-to-Line
Resistance
4
Stationary 2