D.2 ul standards – Yaskawa L1000E AC Drive Technical Manual for CIMR-LE Models for Elevator Applications User Manual
Page 450

D.2 UL Standards
450
YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual
2A0106
R/L1, S/L2, T/L3
70
(1/0)
6.0 to 50
(10 to 1/0)
M8
9 to 11
(79.7 to 97.4)
U/T1, V/T2, W/T3
70
(1/0)
6.0 to 50
(10 to 1/0)
–, +1
–
35 to 50
(2 to 1/0)
B1, B2
–
16 to 50
(6 to 1/0)
16
(6)
16 to 25
(6 to 4)
2A0144
R/L1, S/L2, T/L3
70
(2/0)
6.0 to 95
(10 to 3/0)
M10
18 to 23
(159 to 204)
U/T1, V/T2, W/T3
95
(3/0)
6.0 to 95
(10 to 3/0)
–, +1
–
50 to 70
(1/0 to 3/0)
B1, B2
–
25 to 70
(4 to 2/0)
25
(4)
25
(4)
M8
9 to 11
(79.7 to 97.4)
2A0181
R/L1, S/L2, T/L3
95
(4/0)
70 to 95
(1/0 to 4/0)
M10
18 to 23
(159 to 204)
U/T1, V/T2, W/T3
95
(4/0)
70 to 95
(1/0 to 4/0)
–, +1
–
50 to 95
(1 to 4/0)
+3
–
70 to 95
(1/0 to 4/0)
25
(4)
25 to 35
(4 to 2)
2A0225
R/L1, S/L2, T/L3
70
× 2P
(1/0
× 2P)
70 to 95
(1/0 to 4/0)
M10
18 to 23
(159 to 204)
U/T1, V/T2, W/T3
70
× 2P
(1/0
× 2P)
70 to 95
(1/0 to 4/0)
–, +1
–
50 to 95
(1 to 4/0)
+3
–
70 to 95
(1/0 to 4/0)
25
(4)
25 to 50
(4 to 1/0)
2A0269
R/L1, S/L2, T/L3
95
× 2P
(3/0
× 2P)
95 to 150
(3/0 to 300)
M12
32 to 40
(283 to 354)
U/T1, V/T2, W/T3
95
× 2P
(3/0
× 2P)
95 to 150
(3/0 to 300)
–, +1
–
95 to 150
(3/0 to 300)
+3
–
35 to 150
(2 to 300)
M10
18 to 23
(159 to 204)
35
(3)
35 to 150
(2 to 300)
M12
32 to 40
(283 to 354)
2A0354
R/L1, S/L2, T/L3
120
× 2P
(4/0
× 2P)
95 to 150
(3/0 to 300)
M12
32 to 40
(283 to 354)
U/T1, V/T2, W/T3
120
× 2P
(4/0
× 2P)
95 to 150
(3/0 to 300)
–, +1
–
95 to 150
(3/0 to 300)
+3
–
95 to 150
(3/0 to 300)
M10
18 to 23
(159 to 204)
35
(2)
35 to 150
(2 to 300)
M12
32 to 40
(283 to 354)
Drive Model
Terminal
Recommended
Wire Size
mm
2
(AWG, kcmil)
Wire Range
mm
2
(AWG, kcmil)
Screw
Size
Tightening Torque
N•m (lb.in.)