B8: energy saving, B7-01: droop control gain, B7-02: droop control delay time – Yaskawa L1000E AC Drive Technical Manual for CIMR-LE Models for Elevator Applications User Manual
Page 161: B8-01: energy saving control selection, B8-16: energy saving control constant (ki), B8-17: energy saving control constant (kt), Common_tmo, 2 b: application, Enables or disables the energy saving function

5.2 b: Application
YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual
161
P
a
ra
me
te
r De
ta
ils
5
■
b7-01: Droop Control Gain
Sets the amount of speed reduction when the torque reference is 100%. The gain is set as a percentage of the maximum
output speed. A setting of 0.0% disables the Droop control function.
Figure 5.4
Figure 5.4 Droop Control Gain
■
b7-02: Droop Control Delay Time
Adjusts the responsiveness of Droop control. Reduce the setting if the reaction time is too long, and increase it if hunting
occurs.
◆ b8: Energy Saving
The Energy Saving function can significantly increase the efficiency of an IPM motor.
Note: The Energy Saving function should be used only with a Yaskawa IPM motor.
■
b8-01: Energy Saving Control Selection
Enables or disables the Energy Saving function.
Setting 0: Disabled
Setting 1: Enabled
■
b8-16: Energy Saving Control Constant (Ki)
Enter the Energy Saving value (Ki) as specified on the motor nameplate (for IPM motors only).
■
b8-17: Energy Saving Control Constant (Kt)
Enter the Energy Saving value (Kt) as specified on the motor nameplate (for IPM motors only).
No.
Parameter Name
Setting Range
Default
b7-01
Droop Control Gain
0.0 to 100.0%
0.0%
No.
Parameter Name
Setting Range
Default
b7-02
Droop Control Delay Time
0.03 to 2.00 s
0.05 s
No.
Parameter Name
Setting Range
Default
b8-01
Energy Saving Control Selection
0 or 1
0
No.
Parameter Name
Setting Range
Default
b8-16
Energy Saving Control Constant (Ki)
0.00 to 2.00
0.10
No.
Parameter Name
Setting Range
Default
b8-17
Energy Saving Control Constant (Kt)
0.00 to 2.00
1.00
Speed
Torque
100%
Speed reference
Droop control gain
b7-01
0
common_TMo