S4: rescue operation, B.3 parameter table – Yaskawa L1000E AC Drive Technical Manual for CIMR-LE Models for Elevator Applications User Manual
Page 400

B.3 Parameter Table
400
YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual
■
S4: Rescue Operation
S3-34
(6C4H)
Anti-Rollback Torque Bias 1
Sets the Anti-Rollback Bias applied at small position deviations during Position Lock at start.
Default: 0.0%
Min: 0.0%
Max: 100.0%
S3-35
(6C5H)
Anti-Rollback Torque Bias 2
Sets the Anti-Rollback Bias applied at large position deviations during Position Lock at start.
Default: 0.0%
Min: 0.0%
Max: 100.0%
S3-37
(6C7H)
Position Deviation Level to Apply
ARB Torque Bias 1
Sets the position deviation level to active at Anti-Rollback Torque Bias 1 (S3-34).
Default: 0
Min: 0
Max: 32767
S3-38
(6C8H)
Position Deviation Level to Apply
ARB Torque Bias 2
Determines the position deviation level for when the drive should switch from the torque bias
set in S3-34 to the torque bias set in S3-35.
Default: 0
Min: 0
Max: 32767
S3-39
(6C9H)
Anti-Rollback Integral Gain
Determines the drive’s responsiveness for Anti-Rollback during Position Lock.
Default: 0.00
Min: –30.00
Max: 30.00
S3-40
(6CAH)
Anti-Rollback Movement
Detection
Sets the amount of pulses for movement detection during Anti-Rollback.
Default: 1 pulse
Min: 0 pulse
Max: 100 pulses
S3-41
(6CBH)
Position Lock Gain at Start 2
Reduction
Sets a reduction factor for the Position Lock Gain at Start 2 (Anti-Rollback Gain) set in
parameter S3-02.
Default: 0.50
Min: 0.00
Max: 1.00
No. (Addr.)
Name
Description
Setting
Page
S4-01
(6A6H)
<5> Default setting is determined by the control mode (A1-02).
Light Load Direction Search
Selection
0: Disabled
1: Enabled
2: Enabled for Motor 1 only
Default: 0
Min: 0
Max: 2
S4-02
(6A7H)
Light Load Direction Search
Method
Determines how the drive detects the light load direction.
0: Output Current
1: Regenerative direction detection
Default: 1
Min: 0
Max: 1
S4-03
(6A8H)
Light Load Direction Search Time
Sets the time to perform Light Load Direction Search.
Default: 1.0 s
Min: 0.0 s
Max: 5.0 s
S4-04
(6A9H)
Light Load Direction Search Speed
Reference
Sets the speed reference to use during Light Load Direction Search.
Default:
Min: 0.00%
Max: 20.00%
S4-05
(6AAH)
Rescue Operation Torque Limit
Sets the torque limit used during Rescue Operation.
Default: 100%
Min: 0%
Max: 300%
S4-06
(6CCH)
Rescue Operation Power Supply
Selection
0: Battery
1: UPS (single-phase)
2: UPS (3-phase)
Default: 0
Min: 0
Max: 2
S4-07
(6CDH)
UPS Power
Sets the capacity of the UPS.
Default: 0.0 kVA
Min: 0.0 kVA
Max: 100.0 kVA
S4-08
(6CEH)
UPS Operation Speed Limit
Selection
Determines how a speed limit should be applied to the Rescue Operation speed (d1-25) when
operating from a UPS.
0: Disabled
1: Enabled until Light Load Direction Search is complete
2: Enabled until stop
Default: 2
Min: 0
Max: 2
S4-12
(6D2H)
DC Bus Voltage during Rescue
Operation
Sets the DC bus voltage during Rescue Operation.
Default: 0 V
Min: 0 V
Max: 800 V
S4-13
(6D3H)
Rescue Operation Power Supply
Deterioration Detection Level
Determines at which level of backup power supply deterioration a PF5 fault is triggered.
Default: 80%
Min: 10%
Max: 100%
S4-15
(6DAH)
Speed Reference Selection for
Rescue Operation
Selects the speed reference used for Rescue Operation.
Default: 0
Min: 0
Max: 1
No. (Addr.)
Name
Description
Setting
Page
common
_
CLV
CLV/PM
V/f
OLV
common
_
CLV
CLV/PM
V/f
OLV
common
_
CLV
CLV/PM
V/f
OLV
common
_
CLV
CLV/PM
V/f
OLV
common
_
CLV
CLV/PM
V/f
OLV
common
_
CLV
CLV/PM
V/f
OLV
common
_
CLV
CLV/PM
V/f
OLV
All Modes
common
_
CLV
CLV/PM
V/f
OLV
common
_
All Modes
common
_
All Modes
common
_
All Modes
common
_
All Modes
common
_
All Modes
common
_
All Modes
common
_
common
_
All Modes
common
_
common
_
All Modes
common
_
All Modes
common
_