7.4 Drive Cooling Fans and Circulation Fans
318
YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual
■
Installing the Cooling Fan
NOTICE: Prevent Equipment Damage. Follow cooling fan replacement instructions. Improper cooling fan replacement could result in
damage to equipment. When installing the replacement cooling fan into the drive, make sure the fan is facing upwards. To ensure
maximum useful product life, replace all cooling fans when performing maintenance.
Reverse the procedure described above to reinstall the cooling fan.
1.
Install the replacement fan into the drive, ensuring the alignment pins line up as shown in the figure below.
Figure 7.4
Figure 7.4 Installing the Cooling Fan: 2A0018 to 2A0094, 4A0009 to 4A0049
2.
Properly connect the fan power lines, then place the cable back into the recess of the drive.
Figure 7.5
Figure 7.5 Cooling Fan Power Supply Connectors: 2A0018 to 2A0094, 4A0009 to 4A0049
3.
While pressing in on the hooks on the left and right sides of the fan finger guard, guide the fan finger guard until it
clicks back into place.
Figure 7.6
Figure 7.6 Reattach the Fan Cover: 2A0018 to 2A0094, 4A0009 to 4A0049
4.
Turn the power supply back on and reset the cooling fan operation time for the Maintenance Monitor by setting
o4-03 to 0.
A – Push the connectors together
completely
C – Make sure the pins align
properly.
B – Label facing up
A – Back
B – Front
A
B
C
YEA
_TM
only
A
B
YEA
_TM
only
Y E A _ T
Monly