B.3 Parameter Table
396
YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual
■
o2: Digital Operator Keypad Functions
■
o3: Copy Function
o1-21
(576H)
Roping Ratio
Sets the roping ratio.
1: 1:1
2: 1:2
3: 1:3
4: 1:4
Default: 2
Min: 1
Max: 4
o1-22
(577H)
Mechanical Gear Ratio
Sets the ratio of the gear installed for display unit calculations.
Default:
Min: 0.10
Max: 100.00
o1-23
(174H)
HBB Non Display Select
Shows and hides HBB on the digital operator while the safety signal is being input.
0: Show HBB
1: Hide HBB
Default: 0
Min: 0
Max: 1
<1> The control mode determines the selections available. In V/f Control, only settings 1 through 3 are permitted.
<2> Default setting is determined by the control mode (A1-02).
<5> This parameter appears when the drive displays user-set units (o1-03 = 3).
<6> Default setting and setting range changes when inches are selected for the length units (o1-12 = 1). The setting range becomes 3.70 to 78.00
inches, and the default becomes 15.70 inches.
No. (Addr.)
Name
Description
Setting
Page
o2-01
(505H)
<1> Parameter setting value is not reset to the default value when the drive is initialized.
LO/RE Key Function Selection
0: Disabled
1: Enabled. LO/RE key switches between LOCAL and REMOTE operation.
Default: 0
Min: 0
Max: 1
o2-02
(506H)
STOP Key Function Selection
0: Disabled. STOP key is disabled in REMOTE operation.
1: Enabled. STOP key is always enabled.
Default: 0
Min: 0
Max: 1
o2-03
(507H)
User Parameter Default Value
0: No change.
1: Set defaults. Saves parameter settings as default values for a User Initialization.
2: Clear all. Clears the default settings that have been saved for a User Initialization.
Default: 0
Min: 0
Max: 2
o2-04
(508H)
Drive Model Selection
Enter the drive model. Setting required only if installing a new control board.
Default: Determined by
drive capacity
Min: –
Max: –
o2-05
(509H)
Speed Reference Setting Method
Selection
0: ENTER key must be pressed to enter a speed reference.
1: ENTER key is not required. The speed reference can be adjusted using the up and down
arrow keys only.
Default: 0
Min: 0
Max: 1
o2-06
(50AH)
Operation Selection when Digital
Operator is Disconnected
0: The drive continues operating if the digital operator is disconnected.
1: A fault is triggered (oPr) and the motor coasts to stop.
Default: 0
Min: 0
Max: 1
o2-09
(50DH)
Reserved
–
–
–
No. (Addr.)
Name
Description
Setting
Page
o3-01
(515H)
Copy Function Selection
0: Copy select
1: INV
→ OP READ (Read parameters from the drive, saving them onto the digital operator.)
2: OP
→ INV WRITE (Copy parameters from the digital operator, writing them to the drive.)
3: OP
↔ INV VERIFY (Verify parameter settings on the drive to check if they match the data
saved on the operator.)
To read the drive’s parameter settings into the digital operator, set o3-02 to 1 (to allow reading).
Default: 0
Min: 0
Max: 3
o3-02
(516H)
Copy Allowed Selection
Selects whether the read operation (o3-01 = 1) is enabled or disabled.
0: Read operation prohibited
1: Read operation allowed
Default: 0
Min: 0
Max: 1
No. (Addr.)
Name
Description
Setting
Page
common
_
CLV
CLV/PM
V/f
OLV
common
_
CLV
CLV/PM
V/f
OLV
All Modes
common
_
All Modes
common
_
All Modes
common
_
All Modes
common
_
All Modes
common
_
All Modes
common
_
All Modes
common
_
All Modes
common
_
All Modes
common
_