5.7 H: Terminal Functions
YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual
203
P
a
ra
me
te
r De
ta
ils
5
Setting 14: User-set speed agree 2 (f
ref
/f
set
agree 2)
Closes whenever the actual output speed or motor speed (CLV, CLV/PM) and the speed reference are within the speed
agree width (L4-04) of the programmed speed agree level (L4-03). As the detection level L4-03 is a signed value,
detection works in the specified direction only.
Figure 5.24
Figure 5.24 User Set Speed Agree 2 Example with a Positive L3-04 Value
Refer to L4-03, L4-04: Speed Agreement Detection Level and Detection Width (+/-) on page 220
for more details.
Setting 15: Speed detection 3
Output opens when the output speed or motor speed (CLV, CLV/PM) rises above the detection level set in L4-03 plus the
detection with set in L4-04. The terminal remains open until the output speed or motor speed falls below the level set in
L4-03. As the detection level L4-03 is a signed value, the detection works in the specified direction only.
Figure 5.25
Figure 5.25 Speed Detection 3 Example with a Positive L3-04 Value
Refer to L4-03, L4-04: Speed Agreement Detection Level and Detection Width (+/-) on page 220
for more details.
Status
Description
Open
Output speed or motor speed and speed reference are both outside the range of L4-03 ±L4-04
Closed
Output speed or motor speed and the speed reference are both with in the range of L4-03 ±L4-04
Status
Description
Open
Output speed or motor speed exceeded L4-03 plus L4-04.
Closed
Output speed or motor speed is below L4-03 or has not exceeded L4-03 plus L4-04 yet.
+/- L4-04
L4-03
User Set
Speed Agree 2
OFF
ON
Speed
reference
Speed
reference
Output speed
or motor speed
Output speed
common_
TMonly
L4-04
Speed
detection 3
ON
OFF
L4-03
Output speed
or motor speed
common_
TMonly