2.2 Mechanical Installation
44
YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual
Internal/Flush-Mount
An internal flush-mount requires an installation support set that must be purchased separately. Contact a Yaskawa
representative to order an installation support set and mounting hardware.
Installation Support Set A.
1.
Cut an opening in the enclosure panel for the LED monitor operator as shown in
2.
Mount the LED monitor to the installation support.
3.
Mount the installation support set and LED monitor to the enclosure panel.
Figure 2.8
Figure 2.9 Internal/Flush Mount Installation
Note: Use a gasket between the enclosure panel and the LED monitor in environments with a significant amount of dust or other
airborne debris.
Figure 2.9
Figure 2.10 Panel Cut-Out Dimensions (Internal/Flush-Mount Installation)
Enclosure panel
Unit: mm
Digital Operator
Installation Support Set A
M4 × 10
Phillips truss head screw × 4
(for panel widths between 1 and 1.6)
M3
× 6
Phillips recessed
pan head machine screw × 2
common_TMonly
120
45
59
+0.5
0
89
+0.5
0
Unit : mm