C: tuning, B6: dwell function, B7: droop control – Yaskawa L1000E AC Drive Technical Manual for CIMR-LE Models for Elevator Applications User Manual
Page 370: B8: energy saving, C1: acceleration and deceleration ramps, B.3 parameter table

B.3 Parameter Table
370
YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual
■
b6: Dwell Function
■
b7: Droop Control
■
b8: Energy Saving
◆ C: Tuning
C parameters are used to adjust the acceleration and deceleration ramps, jerk settings, slip compensation, torque
compensation, and carrier frequency selections.
■
C1: Acceleration and Deceleration Ramps
No.(Addr.)
Name
Description
Setting
Page
b6-01
(1B6H)
Dwell Speed at Start
Parameters b6-01 and b6-02 set the speed to hold and the time to maintain that speed at start.
Parameters b6-03 and b6-04 set the speed to hold and the time to maintain that speed at stop.
Default: 0.0%
Min: 0.0%
Max: 100.0%
b6-02
(1B7H)
Dwell Time at Start
Default: 0.0 s
Min: 0.0 s
Max: 10.0 s
b6-03
(1B8H)
Dwell Speed at Stop
Default: 0.0%
Min: 0.0%
Max: 100.0%
b6-04
(1B9H)
Dwell Time at Stop
Default: 0.0 s
Min: 0.0 s
Max: 10.0 s
No.(Addr.)
Name
Description
Setting
Page
b7-01
(1CAH)
Droop Control Gain
Sets the speed reduction gain applied at a torque reference of 100%. Set as a percentage of
motor base speed.
Default: 0.0%
Min: 0.0%
Max: 100.0%
b7-02
(1CBH)
Droop Control Delay Time
Used to adjust the responsiveness of Droop Control.
Default: 0.05 s
Min: 0.03 s
Max: 2.00 s
No.(Addr.)
Name
Description
Setting
Page
b8-01
(1CCH)
Energy Saving Control Selection
0: Disabled
1: Enabled
Default: 0
Min: 0
Max: 1
b8-16
(1F8H)
Energy Saving Control Constant
(Ki)
Enter the Energy Saving value (Ki) as specified on the motor name plate. (for IPM motors only)
Default: 0.10
Min: 0.00
Max: 2.00
b8-17
(1F9H)
Energy Saving Control Constant
(Kt)
Enter the Energy Saving value (Kt) as specified on the motor name plate. (for IPM motors only)
Default: 1.00
Min: 0.00
Max: 2.00
No. (Addr.)
Name
Description
Setting
Page
C1-01
(200H)
Acceleration Ramp 1
Sets the ramp to accelerate from 0 to maximum speed.
Default: 1.50 s
Min: 0.00 s
Max: 600.00 s
C1-02
(201H)
Deceleration Ramp 1
Sets the ramp to decelerate from maximum speed to 0.
C1-03
(202H)
Acceleration Ramp 2
Sets the ramp to accelerate from 0 to maximum speed.
C1-04
(203H)
Deceleration Ramp 2
Sets the ramp to decelerate from maximum speed to 0.
C1-05
(204H)
Acceleration Ramp 3 (Motor 2
Accel Time 1)
Sets the ramp to accelerate from 0 to maximum speed.
All Modes
common
_
common
_
CLV
CLV/PM
V/f
OLV
common
_
CLV
CLV/PM
V/f
OLV
common
_
CLV
CLV/PM
V/f
OLV
common
_
CLV
CLV/PM
V/f
OLV
common
_
CLV
CLV/PM
V/f
OLV
All Modes
common
_
All Modes
common
_
All Modes
common
_
All Modes
common
_
All Modes
common
_