S6-05: brake response error (se4) detection time, S6-10: overacceleration detection level, S6-11: overacceleration detection time – Yaskawa L1000E AC Drive Technical Manual for CIMR-LE Models for Elevator Applications User Manual
Page 263: S6-12: overacceleration detection selection, S6-15: speed reference loss detection, S6-16: restart after baseblock selection, 11 s: elevator parameters, Disables overacceleration detection

5.11 S: Elevator Parameters
YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual
263
P
a
ra
me
te
r De
ta
ils
5
■
S6-05: Brake Response Error (SE4) Detection Time
Sets a delay time for detecting a brake response error (SE4). SE4 is detected when an output terminal set for “Brake
release” (H2- = 50) and an input terminal set for “Brake feedback” (H1- = 79) do not match for the time set to
S6-05.
■
S6-10: Overacceleration Detection Level
If the elevator car accelerates at an abnormal rate, the drive triggers an overacceleration fault (dv6) and the motor coasts
to stop. Parameter S6-10 determines the acceleration rate that triggers the dv6 fault. A setting of 0.0 m/s
2
disables
overacceleration detection.
■
S6-11: Overacceleration Detection Time
Sets the time that the acceleration must exceed the overacceleration detection level before as fault is triggered.
■
S6-12: Overacceleration Detection Selection
Determines the conditions for detecting an overacceleration situation.
Setting 0: Always enabled
Setting 1: During run only
■
S6-15: Speed Reference Loss Detection
Enabled or disables detection for missing speed reference (FrL).
Setting 0: Disabled
Setting 1: Enabled
■
S6-16: Restart after Baseblock Selection
Allows the drive to restart the motor after returning to normal operation from Baseblock state (H1- = 8/9) or from
Safe Torque-Off state (Safe Disable inputs H1 and H2 enabled) while the Up/Down command is still active.
Setting 0: No restart after Baseblock or Safe Torque-Off
Do not restart the motor when leaving the Baseblock or Safe Torque-Off state even if an Up/Down command is still
active.
No.
Parameter Name
Setting Range
Default
S6-05
Brake Response Error (SE4) Detection Time
0 to 10000 ms
500 ms
No.
<1> Default setting is determined by parameter o1-03. If o1-03 is set to 0 through 5, the default is 1.5 m/s
2
. If o1-03 is set to 6, the default is
5.0 ft/s
2
(setting range: 0.0 to 50.0 ft/s
2
).
Parameter Name
Setting Range
Default
S6-10
Overacceleration Detection Level
0.0 to 20.0 m/s
2
1.5 m/s
No.
Parameter Name
Setting Range
Default
S6-11
Overacceleration Detection Time
0 to 5000 ms
50 ms
No.
Parameter Name
Setting Range
Default
S6-12
Overacceleration Detection Selection
0 or 1
0
No.
Parameter Name
Setting Range
Default
S6-15
Speed Reference Loss Detection
0 or 1
1
No.
Parameter Name
Setting Range
Default
S6-16
Restart after Baseblock Selection
0 or 1
0