beautypg.com

2 general description, L1000e model overview – Yaskawa L1000E AC Drive Technical Manual for CIMR-LE Models for Elevator Applications User Manual

Page 27

background image

1.2 General Description

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

27

Re

ce

iv

ing

1

1.2 General Description

L1000E Model Overview

Note: The drive automatically decreases the rated output current when setting higher carrier frequency.

Motor Power

kW (HP)

<1> These values assume the carrier frequency is not set higher than 8 kHz.

<2> These values assume the carrier frequency is not set higher than 5 kHz.

3-Phase 200 V Class

3-Phase 400 V Class

3.7 (5)

2A0018

17.5

<1>

4A0009

9.0

<1>

5.5 (7.5)

2A0022

21.9

<1>

4A0012

11.5

<1>

7.5 (10)

2A0031

31.3

<1>

4A0019

18.5

<1>

11 (15)

2A0041

41.3

<1>

4A0023

22.5

<1>

15 (20)

2A0059

58.8

<1>

4A0030

30.0

<1>

18.5 (25)

2A0075

75.0

<1>

4A0039

38.8

<1>

22 (30)

2A0094

93.8

<1>

4A0049

48.8

<1>

30 (40)

2A0106

106.3

<1>

4A0056

56.3

<1>

37 (50)

2A0144

143.8

<1>

4A0075

75.0

<1>

45 (60)

2A0181

181.3

<2>

4A0094

93.8

<1>

55 (75)

2A0225

225.0

<2>

4A0114

113.8

<1>

75 (100)

2A0269

268.8

<2>

4A0140

140.0

<2>

90 (125)

2A0354

353.8

<2>

4A0188

187.5

<2>

110 (150)

2A0432

432.5

<2>

4A0225

225.0

<2>

132 (175)

-

-

4A0260

260.0

<2>