1 user interface overview, 1 status bar, Figure 3.1.1.1. status bar – Yaskawa PC NC User Manual
Page 64: 2 battery indicator, 3 nc execution status, Table 3.1.3.1: possible execution status values, The nc is not executing, Bufn, The nc is in the n-block buffering status, Pchsc

3 - 7
YASNAC PCNC Operating Manual
Chapter 3: HMI Process Operation
3.1 USER INTERFACE OVERVIEW
The MMI is divided into several areas. At the very top is the status bar, which displays system
status and alarm and warning messages. Below the status bar is the toolbar, which provides quick
and easy access to commonly used functions such as copy and undo. The top level menu buttons
and the Reset button appear at the bottom of the screen. Along the right hand side are the second
level menu items and occasionally, shortcut buttons to other screens. The remainder of the MMI is
what will be referred to as the screen. This area changes based on what is selected in the top and
second level menus. This chapter provides a detailed description of these components.
3.1.1 Status Bar
The status bar occupies the top of the screen, and displays data pertaining to the state of the sys-
tem, as shown in Figure 3.1.1.1 on page 7. It is split into sections that display the battery indica-
tor, NC execution status, motion status, alarm message, warning message time and date.
FIGURE 3.1.1.1. Status Bar
3.1.2 Battery Indicator
At startup, if there is a battery alarm, a broken battery icon
is displayed. Otherwise, a solid
battery
is shown to indicate that everything is normal. After two minutes, this normal battery
indicator will disappear. If a battery alarm occurs, a red "Battery Alarm" message is displayed in
the warning message area. If other warnings occur while the battery alarm exists, they will tempo-
rarily overwrite the battery alarm, but it will be redisplayed when they are cleared.
3.1.3 NC Execution Status
The execution status area (otherwise known as “Running status 1”) can have several values, as
indicated by Table 3.1.3.1 on page 7.
Table 3.1.3.1: Possible Execution Status Values
Text Label
Meaning
STP
The NC is not executing
BUFn
The NC is in the n-block buffering status.
RST
NC is in reset status (Panel reset, Program reset, External reset)
PCHSC
PC High speed cutting mode
GHSC
GHSC form compensation mode