beautypg.com

A2 - 24, Alarm no. : 3091 ( broken spindle pg cable ) – Yaskawa PC NC User Manual

Page 235

background image

A2 - 24

YASNAC PCNC Operating Manual Appendix 2: Alarm Tables

Alarm No. : 3061 to 3068 ( overload )

ALARM CAUSE

CHECK ITEM

COUNTER MEASURE

Turn OFF the power and allow the

Cutting Conditions

Check if the alarm occurred during

servo motors to cool. After cooling

machining.

change the machining conditions

and restart operation.

Guideways are not lubricated

If guideways are lubricated check for

Contact the machine tool builder or your

properly causing heavy axis

damage or obstructions.

Yaskawa representative.

movements.

Alarm No. : 3081 to 3088 ( Broken PG Cable )

ALARM CAUSE

CHECK ITEM

COUNTER MEASURE

Signal cables between the NC and the AC

Check cable and connectors.

If cable is damaged replace.

servo drive unit are broken or loose.

Check to make sure connectors are

plugged in securely.

Faulty PG cable breakage detection circuit.

Check if the alarm occurs when you first

Contact your Yaskawa representative.

POWER ON even if the cables are

connected properly.

Error in motor type parameter setting.

Check the motor type setting parameters

Correct the setting.

( pm1061 to pm1065 ) if "0" has been set.

Alarm No. : 3091 ( Broken Spindle PG Cable )

ALARM CAUSE

CHECK ITEM

COUNTER MEASURE

Signal cables between the NC and the AC

Check cable and connectors.

If cable is damaged replace.

servo drive unit are damaged or loose.

Check to make sure connectors are

plugged in securely.