A2 - 24, Alarm no. : 3091 ( broken spindle pg cable ) – Yaskawa PC NC User Manual
Page 235

A2 - 24
YASNAC PCNC Operating Manual Appendix 2: Alarm Tables
Alarm No. : 3061 to 3068 ( overload )
ALARM CAUSE
CHECK ITEM
COUNTER MEASURE
Turn OFF the power and allow the
Cutting Conditions
Check if the alarm occurred during
servo motors to cool. After cooling
machining.
change the machining conditions
and restart operation.
Guideways are not lubricated
If guideways are lubricated check for
Contact the machine tool builder or your
properly causing heavy axis
damage or obstructions.
Yaskawa representative.
movements.
Alarm No. : 3081 to 3088 ( Broken PG Cable )
ALARM CAUSE
CHECK ITEM
COUNTER MEASURE
Signal cables between the NC and the AC
Check cable and connectors.
If cable is damaged replace.
servo drive unit are broken or loose.
Check to make sure connectors are
plugged in securely.
Faulty PG cable breakage detection circuit.
Check if the alarm occurs when you first
Contact your Yaskawa representative.
POWER ON even if the cables are
connected properly.
Error in motor type parameter setting.
Check the motor type setting parameters
Correct the setting.
( pm1061 to pm1065 ) if "0" has been set.
Alarm No. : 3091 ( Broken Spindle PG Cable )
ALARM CAUSE
CHECK ITEM
COUNTER MEASURE
Signal cables between the NC and the AC
Check cable and connectors.
If cable is damaged replace.
servo drive unit are damaged or loose.
Check to make sure connectors are
plugged in securely.