Yaskawa PC NC User Manual
Page 374
A3 - 134
YASNAC PCNC Operating Manual
APPENDIX 3: Parameter Tables
Reference Point Return
Address
Bit
Description
Register
Units
Minimum
Value
Maximum
Value
Long Description
1044
5
1st axis Zero return Virtual C
phase motor 1 rev.
1: Use pm1851
0: Use pm1821
0
1
1045
5
2nd axis Zero return Virtual C
phase motor 1 rev.
1: Use pm1851
0: Use pm1821
0
1
1046
5
3rd axis Zero return Virtual C
phase motor 1
1: Use pm1851
0: Use pm1821
0
1
1047
5
4th axis Zero return Virtual C
phase motor 1 rev.
1: Use pm1851
0: Use pm1821
0
1
1048
5
5th axis Zero return Virtual C
phase motor 1 rev.
1: Use pm1851
0: Use pm1821
0
1
2521
1st axis reference point return
approach speed
mm/min,
deg/min
0
32767
2522
2nd axis reference point return
approach speed
mm/min,
deg/min
0
32767
2523
3rd axis reference point return
approach speed
mm/min,
deg/min
0
32767
2524
4th axis reference point return
approach speed
mm/min,
deg/min
0
32767
2525
5th axis reference point return
approach speed
mm/min,
deg/min
0
32767
2531
1st axis reference point return
creep speed
mm/min,
deg/min
0
32767
2532
2nd axis reference point return
creep speed
mm/min,
deg/min
0
32767
2533
3rd axis reference point return
creep speed
mm/min,
deg/min
0
32767
2534
4th axis reference point return
creep speed
mm/min,
deg/min
0
32767
2535
5th axis reference point return
creep speed
mm/min,
deg/min
0
32767
4001
6
Occurrence of Alarm cycle start
before Zero return
0: An alarm occurs
1: An alarm does not occur
0
1
Conforms to pm4018
d0-d4