Yaskawa PC NC User Manual
Page 189

4 - 27
YASNAC PCNC Operating Manual
Chapter 4: Maintenance
(b) Spindle zero speed signal is not input.
If the NC enters this status after the execution of “M05” command, check the I/O signals
of #1000s at the I/O section by referring to the ladder chart supplied by the machine tool
builder.
(c) Others
If the NC enters this status after the execution of “M19” or “M20” (spindle orientation
command), check the I/O signals related with spindle orientation by referring to the ladder
chart supplied by the machine tool builder.
(10)Edit Operation is Impossible
(a) The edit lock signal is input.
Check I/O monitor #3007 D2.
Normal: #3007 D2 = 0
If “#3007 D2 = 1”, program edit is impossible.
(b) Edit lock is set by the parameter (pm0000 D7).
Set “pm0000 D7 = 0” to cancel the edit lock setting.
(c) Others
The corresponding alarm message is displayed.
OVER MEM CAP !
TOO MANY PROGS !
ALREADY IN !
Delete unnecessary programs and edit the program again.
(11)Skip Function (G31) Failure
The skip signal has not been input.
•
Check ON/OFF status of the skip signals by checking the I/O monitor #3514 D0 to D2.
•
Check the operation of proximity switches, etc.
- Tag Generator (30 pages)
- MP3300iec (82 pages)
- 1000 Hz High Frequency (18 pages)
- 1000 Series (7 pages)
- PS-A10LB (39 pages)
- iQpump Micro User Manual (300 pages)
- 1000 Series Drive Option - Digital Input (30 pages)
- 1000 Series Drive Option - CANopen (39 pages)
- 1000 Series Drive Option - Analog Monitor (27 pages)
- 1000 Series Drive Option - CANopen Technical Manual (37 pages)
- 1000 Series Drive Option - CC-Link (38 pages)
- 1000 Series Drive Option - CC-Link Technical Manual (36 pages)
- 1000 Series Drive Option - DeviceNet (37 pages)
- 1000 Series Drive Option - DeviceNet Technical Manual (81 pages)
- 1000 Series Drive Option - MECHATROLINK-II (32 pages)
- 1000 Series Drive Option - Digital Output (31 pages)
- 1000 Series Drive Option - MECHATROLINK-II Technical Manual (41 pages)
- 1000 Series Drive Option - Profibus-DP (35 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (36 pages)
- Z1000U HVAC MATRIX Drive Quick Start (378 pages)
- 1000 Series Operator Mounting Kit NEMA Type 4X (20 pages)
- 1000 Series Drive Option - Profibus-DP Technical Manual (44 pages)
- CopyUnitManager (38 pages)
- 1000 Series Option - JVOP-182 Remote LED (58 pages)
- 1000 Series Option - PG-X3 Line Driver (31 pages)
- SI-EN3 Technical Manual (68 pages)
- JVOP-181 (22 pages)
- JVOP-181 USB Copy Unit (2 pages)
- SI-EN3 (54 pages)
- SI-ET3 (49 pages)
- MECHATROLINK-III (35 pages)
- EtherNet/IP (50 pages)
- SI-EM3 (51 pages)
- 1000-Series Option PG-E3 Motor Encoder Feedback (33 pages)
- 1000-Series Option SI-EP3 PROFINET (56 pages)
- PROFINET (62 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (45 pages)
- SI-EP3 PROFINET Technical Manual (53 pages)
- A1000 Drive Option - BACnet MS/TP (48 pages)
- 120 Series I/O Modules (308 pages)
- A1000 12-Pulse (92 pages)
- A1000 Drive Software Technical Manual (16 pages)
- A1000 Quick Start (2 pages)
- JUNMA Series AC SERVOMOTOR (1 page)
- A1000 Option DI-101 120 Vac Digital Input Option (24 pages)