A3 - 60 – Yaskawa PC NC User Manual
Page 300
A3 - 60
YASNAC PCNC Operating Manual
APPENDIX 3: Parameter Tables
pm5404
Time from ESP signal rising to base
block on 4th axis
msec
0
32767
multiply of 10msec
pm5405
Time from ESP signal rising to base
block on 5th axis
msec
0
32767
multiply of 10msec
pm5410
Time from sending M,S,T code to
sending of MF,SF,TF
msec
0
32767
pm5413
Parts counter keep memory address
0
7999
Parts counter use 2
bytes keep memory
area
pm5420
Software switch, input keep
memory start number
7000
7999
pm5421
Software switch, output keep
memory start number
7000
7999
pm5426
Spindle tool number stored keep
memory number
7000
7999
pm5427
Program restart switch, keep
memory number
7000
7999
pm5428
Manual skip signal, keep
memory number (work
pre-setter
)
7000
7999
pm6130
No.1 position monitor, check axis
number
0
5
pm6131
No.2 position monitor, check axis
number
0
5
pm6132
No.3 position monitor, check axis
number
0
5
pm6133
No.4 position monitor, check axis
number
0
1
pm6134
No.5 position monitor, check axis
number
0
5
pm6135
No.6 position monitor, check axis
number
0
5
pm6136
No.7 position monitor, check axis
number
0
5
pm6137
No.8 position monitor, check axis
number
0
5
pm6920
No.1 position monitor forward dir area
boundary value
0.001mm
-999999999
999999999
pm6921
No.2 position monitor forward dir area
boundary value
0.001mm
-999999999
999999999
pm6922
No.3 position monitor forward dir area
boundary value
0.001mm
-999999999
999999999
pm6923
No.4 position monitor forward dir area
boundary value
0.001mm
-999999999
999999999
pm6924
No.5 position monitor forward dir area
boundary value
0.001mm
-999999999
999999999
Address
Bit
Description
Register
Units
Minimum
Value
Maximum
Value
Long Description