A3 - 112 – Yaskawa PC NC User Manual
Page 352

A3 - 112
YASNAC PCNC Operating Manual
APPENDIX 3: Parameter Tables
811
1st axis skip position
0.001mm
-999999999
999999999
Coordinate values
when skip signal is
operating (1st axis)
812
2nd axis skip position
0.001mm
-999999999
999999999
Coordinate values
when skip signal is
operating (2nd axis)
813
3rd axis skip position
0.001mm
-999999999
999999999
Coordinate values
when skip signal is
operating (3rd axis)
814
4th axis skip position
0.001mm
-999999999
999999999
Coordinate values
when skip signal is
operating (4th axis)
815
5th axis skip position
0.001mm
-999999999
999999999
Coordinate values
when skip signal is
operating (5th axis)
4001
7
Cycle start interlock when system
number
0
1
System number switch
“1” or pm0109 = 1
5012
0
Servo power ON method
0
1
3
SVMX OFF function
0
1
5400
Time from base block cancel to
brake release
msec
0
32767
5401
Time from ESP signal rising to base
block on 1st axis
msec
0
32767
multiply of 10msec
5402
Time from ESP signal rising to base
block on 2nd axis
msec
0
32767
multiply of 10msec
5403
Time from ESP signal rising to base
block on 3rd axis
msec
0
32767
multiply of 10msec
5404
Time from ESP signal rising to base
block on 4th axis
msec
0
32767
multiply of 10msec
5405
Time from ESP signal rising to base
block on 5th axis
msec
0
32767
multiply of 10msec
5410
Time from sending M,S,T code to
sending of
msec
0
32767
5413
Parts counter keep memory address
0
7999
Parts counter use 2
bytes keep memory
area
5420
Software switch, input keep
memory start number
7000
7999
5421
Software switch, output keep
memory start number
7000
7999
5426
Spindle tool number stored keep
memory number
7000
7999
5427
Program restart switch, keep
memory number
7000
7999
Address
Bit
Description
Register
Units
Minimum
Value
Maximum
Value
Long Description