Table 4.1.7.1: jog feedrate, Set for parameter pm2400, Set for parameter pm2401 – Yaskawa PC NC User Manual
Page 181: Set for parameter pm2402, Set for parameter pm2403, Set for parameter pm2404, Set for parameter pm2405, Set for parameter pm2406, Set for parameter pm2407, Set for parameter pm2408
4 - 19
YASNAC PCNC Operating Manual
Chapter 4: Maintenance
(c) Jog feedrate signal is not input, or job feedrate setting parameter is incorrect
Check the bit status on the I/O monitor screen whether it changes according to
the operation of the JOG FEEDF.ATE switch, and also check if the setting for
the parameters is correct.
Table 4.1.7.1: Jog Feedrate
STEP
I/O MONITOR #3002
JOG FEEDRATE
D4
D3
D2
D1
D0
JV16
JV8
JV4
JV2
JV 1
1
0
0
0
0
0
Set for parameter pm2400
2
0
0
0
0
1
Set for parameter pm2401
3
0
0
0
1
0
Set for parameter pm2402
4
0
0
0
1
1
Set for parameter pm2403
5
0
0
1
0
0
Set for parameter pm2404
6
0
0
1
0
1
Set for parameter pm2405
7
0
0
1
1
0
Set for parameter pm2406
8
0
0
1
1
1
Set for parameter pm2407
9
0
1
0
0
0
Set for parameter pm2408
10
0
1
0
0
1
Set for parameter pm2409
11
0
1
0
1
0
Set for parameter pm2410
12
0
1
0
1
1
Set for parameter pm2411
13
0
1
1
0
0
Set for parameter pm2412
14
0
1
1
0
1
Set for parameter pm2413
15
0
1
1
1
0
Set for parameter pm2414
16
0
1
1
1
1
Set for parameter pm2415
17
1
0
0
0
0
Set for parameter pm2416
18
1
0
0
0
1
Set for parameter pm2417
19
1
0
0
1
0
Set for parameter pm2418
20
1
0
0
1
1
Set for parameter pm2419
21
1
0
1
0
0
Set for parameter pm2420
22
1
0
1
0
1
Set for parameter pm2421
23
1
0
1
1
0
Set for parameter pm2402
24
1
0
1
1
1
Set for parameter pm2423
25
1
1
0
0
0
Set for parameter pm2424
26
1
1
0
0
1
Set for parameter pm2425
27
1
1
0
1
0
Set for parameter pm2426
28
1
1
0
1
1
Set for parameter pm2427
29
1
1
1
0
0
Set for parameter pm2428
30
1
1
1
0
1
Set for parameter pm2429
31
1
1
1
1
0
Set for parameter pm2430
32
1
1
1
1
1
Set for parameter pm2431