Configuring QOS on the GigE switch

20.If you have a trunk, verify that for the default VLAN the trunk is displayed in the

Tagged Ports column.

21.If you have two switches, repeat this procedure for the other switch.

22.Close the switch configuration application.

Configuring QOS on the GigE switch

Prerequisites for this procedure are as follows:

• The switch is HP ProCurve switch 29xx series.

• Trunks, VLANs and all other configuration is complete.

• The switch has an IP address

• You have network access to the switch

Use this procedure to make the Quality of Service (QOS) setting on the HP ProCurve
switch 29xx series.

1. If you have not already done so, from a network connected PC open the MS-DOS

command prompt and login to the switch as administrator, as follows:

a. Telnet to the switch. For example, if the switch’s IP address is 192.168.40.12,

you type the following, then press

Enter

.

telnet 192.168.40.12

b. Press

Enter

one or more times until the switch’s username prompt appears.

c. Type the switch’s administrator username and press

Enter

, then type the

switch’s administrator password and press

Enter

. The switch console command

(CLI) prompt appears.

2. Type the following, then press

Enter

:

config

You are now in configuration mode.

3. Type the following, then press

Enter

:

show qos vlan

The screen displays VLAN information. Note the ID number of the Media (iSCSI)
VLAN. It should be 60, as follows:

VLAN priorities

VLAN ID Apply rule | DSCP Priority

------- ----------- + ------ -----------

1 No-override | No-override

60 No-override | No-override

a. Assign the Media VLAN the QOS priority of 3. For example, if the VLAN ID