beautypg.com

Configuring the redundant server b – Grass Valley K2 Summit Storage Area Network v.7.1 User Manual

Page 188

background image

26 October 2009

K2 Storage Area Network Installation and Service Manual

188

Configuring the redundant server B

iSCSI Bridge Server
Configuration

This page manages the
components that bridge
between iSCSI (the GigE
media network) and the
Fibre Channel connection to
the RAID storage. You
configure network settings
on the iSCSI adapters and
the page validates that the
Fibre Channel adapter is in
place and that the media
RANKs are visible as iSCSI
targets.

NOTE: The iSCSI
adapters on this
server must be on a
different subnet
than those on its
redundant server
partner.

Select

Backup

.

Select an iSCSI adapter and click

Modify

. A network configuration

dialog box opens. Verify or enter the media network IP address and
subnet mask and click

Apply

.

Do not configure the second iSCSI adapter. It is not used on a L10R
system.
To verify drives, click

Check

then

View Target Drives

. You should see

all your media drives listed.
Click

Next

.

Metadata Server
Configuration

You do not need to enter or configure anything on this page.
Click

Next

.

On this page…

Do this…

This manual is related to the following products: