Configuring raid network and snmp settings – Grass Valley K2 Summit Storage Area Network v.7.1 User Manual
Page 160

26 October 2009
K2 Storage Area Network Installation and Service Manual
160
Configuring RAID
•
“Binding disk modules”
Refer to
“Prerequisites for initial configuration” on page 154
to confirm that the
RAID storage is ready for configuration.
Configuring RAID network and SNMP settings
Use the Storage Utility to configure the following settings for the Level 10 RAID
controller:
• IP address
• Subnet mask
• Gateway Address
• SNMP trap destinations
For L10 RAID, network and SNMP settings are set and stored on the RAID controller
module, so the combined RAID storage devices, including the optional Expansion
chassis, exist as a single entity on the control network.
The RAID storage device is configured by default for the SNMP community name
“public”. If your site’s policies require using a different SNMP community name,
contact your Grass Valley representative.
To configure these settings, do the following:
1. Launch Storage Utility from the K2 System Configuration application as in the
previous procedure.
2. As prompted, wait while Storage Utility gathers system information, then Storage
Utility opens.
3. In Storage Utility tree view, expand the node for the L10 RAID, right-click the icon
for a L10 RAID controller, and select
Configuration | Network Properties
.
The Controller Network Settings dialog box opens.