beautypg.com

Configuring raid network and snmp settings – Grass Valley K2 Summit Storage Area Network v.7.1 User Manual

Page 160

background image

26 October 2009

K2 Storage Area Network Installation and Service Manual

160

Configuring RAID

“Binding disk modules”

Refer to

“Prerequisites for initial configuration” on page 154

to confirm that the

RAID storage is ready for configuration.

Configuring RAID network and SNMP settings

Use the Storage Utility to configure the following settings for the Level 10 RAID
controller:

• IP address

• Subnet mask

• Gateway Address

• SNMP trap destinations

For L10 RAID, network and SNMP settings are set and stored on the RAID controller
module, so the combined RAID storage devices, including the optional Expansion
chassis, exist as a single entity on the control network.

The RAID storage device is configured by default for the SNMP community name
“public”. If your site’s policies require using a different SNMP community name,
contact your Grass Valley representative.

To configure these settings, do the following:

1. Launch Storage Utility from the K2 System Configuration application as in the

previous procedure.

2. As prompted, wait while Storage Utility gathers system information, then Storage

Utility opens.

3. In Storage Utility tree view, expand the node for the L10 RAID, right-click the icon

for a L10 RAID controller, and select

Configuration | Network Properties

.

The Controller Network Settings dialog box opens.

This manual is related to the following products: